P.804 – Canon imagePROGRAF iPF6400S User Manual
Page 804

•
Multiple printer management
For details, refer to the Color Calibration Management Console instructions.
(See "Color Calibration Management Console (Windows).")
(See "Color Calibration Management Console (Mac OS).")
Switching the White/Black Backing Plate (Optional) Color
Switching the White/Black Backing Plate (Optional) Color
The Spectrophotometer Unit (option) uses the White/Black Backing Plate to measure colors. Choose white (white
backing) or black (black backing) based on your particular printing application.
Important
•
The White/Black Backing Plate is fragile. Do not bend or drop it.
1
If the Up-down Unit is lowered, open the Spectropho-
tometer Unit Cover and lift up the central part (near the
blue label) of the Up-down Unit.
Important
•
Lifting up the ends of the Up-down Unit may cause damage.
2
Turn the printer off.
(See "Turning the Printer On and Off.")
Important
•
If you change the color of the White/Black Backing Plate while the printer is turned on, the printer will not recognize
that the color has changed.
3
Check the selected color.
The selected color is the color where the triangle to the
left of the Spectrophotometer Eject Guide and the trian-
gle to the left of the White/Black Backing Plate meet.
4
Hold the end of the White/Black Backing Plate attached
to the Spectrophotometer Eject Guide and move it in
the direction of the arrow to release it.
Important
•
When handling the White/Black Backing Plate, do not touch
the white backing plate (a) or black backing plate (b) directly
with your hands.
If the surface becomes dirty or scratched, the printer may not
be able to obtain the correct color measurement results.
Switching the White/Black Backing Plate (Optional) Color
iPF6400S
Color Management
Color Calibration
804