4 HygroGen2 Enhanced Features
Available Features
Low Temperature and Humidity Range Extensions extend the limits of points that can be set on the
instrument, creating chamber conditions down to -5°C and from 2%rh up to 99%rh.
AutoCal allows you to pre-program a series of set-points and times, and record the instrument’s
progression through them in a PDF Calibration Certificate which is written to an external USB disk drive.
Any values recorded on ROTRONIC HygroClip probes attached to the HygroGen2 via USB adaptors are
recorded in the certificate. Probes can be set to automatically adjust to match the HygroGen2 reference
probe at predetermined values.
AutoCal+ (External Reference) extends the functionality of AutoCal, by integrating MBW/RHS chilled
mirror hygrometers (supplied separately) as the external reference.
Remote Control gives the ability to remotely control the HygroGen2 over a network. As part of this,
there is a dial-back function so that ROTRONIC support personnel can log onto the instrument to offer
support.
Please see the following sections for detailed descriptions of the operation of each of the Enhanced
Features.
Feature Activation
HygroGen2 features are enabled by the application of an activation code. Please purchase an activation
code for the desired features from your ROTRONIC dealer. You will need to supply your HygroGen2
serial number (see rear of instrument) when ordering the code. Alternatively, go to the Settings screen
and select the appropriate feature from the Settings drop-down menu and supply the code as given in
the format “XXXXXX.YY-Z-ABC”.
To activate Enhanced Features on your HygroGen2, you will need a USB keyboard plugged into the
HygroGen2 to type in the supplied code, which will be a 16-digit string of numbers and letters in
CAPITALS. The code will activate all the features you have purchased. If you have previously purchased
one or more features and you want to add another, a new code will be supplied enabling both/all
features.
To activate the upgrade features, go to the Settings screen, select the “Updates” drop-down menu and
choose “Upgrade Features”. Type in the supplied code, ensuring there are no extra characters or spaces
at the end of the string. The green lights will light up displaying the purchased Enhanced Features, which
will be available immediately.