NORD Drivesystems BU0040 User Manual
Page 57
3 ControlBoxes
– SK POT1-1
BU 0040 GB-0113
Subject to technical alterations
57
3.2.2
Parameterisation
For the functions of the control box SK POT1-1, some parameters must be changed, according to the frequency
inverter and the options.
The most important of these are listed below. For further information, please refer to the manual for the relevant
frequency inverter.
Frequency inverter
SK 2x0E
1)
SK 2x5E:
SK 300E
SK 5xxE SK
700E SK 750E
+ SK xU4-IOE
+ SK xU4-24V-
Function
Input
(Parameter)
{Function}
Enable right
DIN1 (P420[-01])
{01}
DIN5 (P480[-05])
{01}
DIN1 (P420[-01])
{01}
DIN2 (P421)
{01}
DIN1 (P420)
{01}
Enable left
DIN2 (P420[-02])
{02}
DIN6 (P480[-06])
{02}
DIN2 (P420[-02])
{02}
DIN3 (P422)
{02}
DIN2 (P421)
{02}
Analog input
AIN1 (P400[-01])
{01}
AIN1 (P400[-03])
{01}
AIN1 (P400[-07])
{01}
and
DIN3 (P420[-03])
{26}
AIN1 (P400)
{01}
AIN1 (P400)
{01}
Automatic start
(if required)
No input
(P428)
{1}
No input
(P428)
{1}
No input
(P428)
{1}
No input
(P428)
{1} or {2}
No input
(P428)
{1}
1)
For devices with an AS interface (SK 220E and SK 230E) analog input 1 is not present and therefore analog input 2 must be used.
Accordingly, parameter P400[-02] must be set to Function {01}.
3.2.3
Technical data
Name
Value
Direction selector switch
Left - OFF - Right
Potentiometer
0 … 100% (0 – 10V)
Ambient temperature
0°C … 40°C
Protection class
IP66
Dimensions (L x W x D)
(120 x 80 x 80)mm
Weight approx.
1.0 kg
Wall-mounting
possible with 4 holes at the rear
Connection cable length
approx. 3m