NORDAC Control and Parameter Boxes
48
Subject to technical alterations
BU 0040 GB-0113
P1
P2
Connections
Connection to the horizontal terminal bar is by means of a
4-wire cable.
Settings on the frequency inverter
Name
Parameter number
Value
Notes
Function, digital output 1
P434 [-01]
{00} or {07}*
Setting {07} corresponds to the default value
* Other settings are not permissible and result in the loss of communication between the Simple Setpoint Box and the frequency inverter in IO-C mode.
Information
Deactivation of the IO functions
In "IO-C" mode, the parameterised functions of the IOs "Digital Input 1 (parameter (P420[-01])) and "Digital
Output 1" (parameter (P434[-01])) are deactivated. The condition for this is that Digital Output 1 is parameterised
either to "No function" {00} or the default setting "Fault" {07}.
The DIP switch S1:
3 … 5 of the frequency inverter ("BUS" / "IO") must be left in the factory setting ("OFF" or"0")
in order to prevent communication faults on the frequency inverter.
Information
Parameter P434[-01]
– Disabling the IO-C mode
If the parameter (P434[-
01]) is set to values ≠ {00} or ≠ {07}, the IO-C mode of the SK SSX-3A is barred when the
frequency inverter restarts.
Boot UP display
After switching on, the lettering briefly appears in the display
Operation
Control of the Simple Setpoint Box SK SSX-3A in this mode is identical to that of the SimpleBox SK CSX-3H/ -3E
(see Section 2.2).
Control commands (enable/stop/direction of rotation) and setpoints from the box are only recognised by the
frequency inverter if it has not been enabled from other sources (e.g. digital input of the FI) (priority switching). This
also means that the drive of the source from which it was started must also be set back to Stop.
24V
GND/0V
44
40
B1
C1
24V voltage supply from SK 2xxE
b)
I/O connection for FI setpoint values
IN
OUT
Connection for IO-C mode
SK SSX-3A
SK 2xxE-
44
40
21
1
I/O connection for actual FI values
a) If available on the frequency inverter
b) Supply via terminal 43 or 44, according to the device 24V
DC
– Supply by separate mains unit is also possible
c) Observe correct voltage (24V
DC
), if necessary, provide the supply voltage to the SK SSX3A separately.