Display
Error number
Fault
Text in the ParameterBox
Cause
Remedy
Identification errors
220
Unknown device
Device ID not found.
The connected inverter is not listed in the database of the ParameterBox;
no communication can be established.
Please contact your Getriebebau Nord Representative.
221
Software version not recognised
The software of the connected frequency inverter is not listed in the
ParameterBox database, no communication can be set up.
Please contact your Getriebebau Nord Representative.
222
Inverter extension level not recognised
An unknown module has been detected in the frequency inverter (Customer
interface / Special extension).
Please check the modules installed in the frequency inverter
If necessary, check the software version of the ParameterBox
and the frequency inverter.
223
Bus configuration has changed
After restoring the last Bus configuration, a device is reported that is
different from the one stored.
This error can only occur if the parameter >Auto. Bus Scan< is set to OFF
and another device has been connected to the ParameterBox.
Activate the automatic Bus scan function.
224
Device is not supported
The inverter type entered in the ParameterBox is not supported!
The ParameterBox cannot be used with this frequency inverter.
225
The connection to the
inverter is blocked
Access to a device that is not online (previous Time Out error).
Carry out a bus scan via the parameter >Bus Scan< (P1001).
ParameterBox operating error
226
Source and target are different
devices
Copying objects of different types (from / to different inverters) is not
possible.
227
Source is empty
Copying of data from a deleted (empty) storage medium
228
This combination is not permitted
Target and source for the copying function are the same. The command
cannot be carried out.
229
Object selected is empty
Parameterisation attempt of a deleted storage medium
230
Different software versions
Warning
Copying objects with different software versions can lead to problems when
transferring parameters.
231
Invalid password
Attempt to alter a parameter without a valid Box password being entered in
parameter >Box Password< P 1306.
232
Bus scan only during operation: online
A bus scan (search for a connected frequency inverter) is only possible
when in ONLINE mode.