3 technical data, Warnings, Inverter control error – NORD Drivesystems BU0040 User Manual
Page 40: Error message from inverter
NORDAC Control and Parameter Boxes
40
Subject to technical alterations
BU 0040 GB-0113
Display
Error number
Fault
Text in the ParameterBox
Cause
Remedy
Warnings
240
Overwrite data?
→ Yes
No
These warnings indicate that there is a possibly significant change which
needs additional confirmation.
Once the next procedure has been selected, it must be confirmed with the
"ENTER" key.
241
Delete data?
→ Yes
No
242
Different SW version?
→ Next
Cancel
243
Different series?
→ Next
Cancel
244
Delete all data?
→ Yes
No
Inverter control error
250
This function is not enabled
The function requested is not enabled at the frequency inverter parameter
interface.
Change the value of the parameter >Interface< of the connected
inverter to the required function.
More detailed information can be obtained from the operating
instructions for the frequency inverter.
251
Control command was not successful
The control command cannot be implemented by the frequency inverter, as
a higher priority function, e.g. Quick stop or an OFF signal to the control
terminals of the frequency inverter is present.
252
Control is not possible offline
Call up of a control function in Offline mode.
Change the operating mode of the ParameterBox in the
parameter >Operating Mode< P1302 to Online and repeat the
action.
253
Error acknowledgement not successful
The acknowledgement of an error at the frequency inverter was not
successful, the error message remains in effect.
Error message from inverter
Inverter error
number
Inverter error text
A fault has occurred in the inverter with the number displayed. The inverter
error number and text are displayed.
2.3 Technical data
Name
SK TU3-PAR SK PAR-2H
SK PAR-2E
SK PAR-3H
SK PAR-3E
SK CSX-3H
SK CSX-3E SK TU3-CTR
Control voltage
4.5V
DC
… 30V
DC
Power
consumption
approx. 1.3 W approx. 1.3 W approx. 1.3 W approx. 1.3 W approx. 1.3 W approx. 1.0 W approx. 1.0 W approx. 1.0 W
Display
Plain text display
4-digit, 7-segment display
Interfaces
SPI-Bus
RS485
RS485
RS485 and
RS485
RS485
RS485
SPI-Bus
Ambient
temperature
0°C … 40°C
Protection class
IP20
IP54
1)
IP54
2)
IP54
3)
IP54
2)
IP54
3)
IP54
2)
IP20
Dimensions
(L x W x D)
(73 x 100 x 20)
mm
(90 x 145 x 27)
mm
(100 x 162 x
38) mm
(117 x 73 x 24)
mm
(128 x 83 x 32)
mm
(117 x 73 x 24)
mm
(128 x 83 x 32)
mm
(73 x 100 x 20)
mm
Weight approx.
0,2 kg
0.7 kg
0.5 kg
0.2 kg
0.6 kg
0.2 kg
0.6 kg
0,2 kg
Connection
cable length
Not possible
approx. 3m
approx. 2m
approx. 2m
Not possible
1)
with plug inserted
2)
on the front side
3)
on plug socket IP20