2 Parameter Boxes
– Display and control
BU 0040 GB-0113
Subject to technical alterations
23
Parameterisation with the SimpleBox / ControlBox
The parameterisation of the frequency inverter can be performed in the various operating states. All parameters
can always be changed online. Switching to the parameter mode occurs in different ways depending upon the
operating states and the enabling source.
1. If there is no enable (if necessary, press the STOP key
) via the SimpleBox, the control terminals or a
serial interface, it is still possible to switch to the parameterisation mode directly from the operating value
display with the value keys
or
.
P 0 _ _
...
P 7 _ _
2. If an enable is present via the control terminals or a serial interface and the frequency inverter is producing
an output frequency, it is also possible to switch to the parameterisation mode directly from the operating
value display using the value keys
or
.
P 0 _ _
...
P 7 _ _
3. If the inverter is enabled via the ControlBox (START key
), the parameterisation mode can be accessed
by pressing the START and ENTER keys (
+
or
) simultaneously.
4. Switching back to the control mode is achieved by pressing the START key
.
The following illustration is for the SimpleBox and applies accordingly for the ControlBox.
Changing parameter values
To access the parameter section, one of the value keys,
or
must be pressed. The display changes to the
menu group display
P 0 _ _
...
P 7 _ _
. After pressing the ENTER key
or
, access to the menu group is
obtained and the required parameter can be selected with the value keys.
All parameters are arranged in order in the individual menu groups in a continuous scroll pattern. It is therefore
possible to scroll forwards and backwards within this section.
Each parameter has a parameter number
P x x x
. The significance and description of the parameters starts in
Section 5 "Parameterisation"
OK
OK
P1
P2
NORD
DRIVESYSTEMS
OK
SK CSX-3H
Select menu group
or
display parameter value or
adopt parameter value
Select function
Next menu group or
parameter number
Value -
+
Load factory setting
Parameter set display
P set No..
P1
P2
1
Off
Off
2
On
Off
3
Off
On
4
On
On
Switch from
parameterisation to control
(with enable (START))
Value +
Previous menu group or
parameter number
Value function
One menu level back or do
not adopt changed value
Pressed simultaneously:
Switching from control to
parameterisation while the
drive is running
Switch from
parameterisation to control
(without enable (STOP))