NORD Drivesystems BU0040 User Manual
Page 24
NORDAC Control and Parameter Boxes
24
Subject to technical alterations
BU 0040 GB-0113
NOTE:
Some parameters, e.g.:
P465, P475, P480…P483, P502, P510, P534, P701…P706, P707, P718,
P740/741 and P748 (depending on the inverter series) have additional levels (arrays), in which
further settings can be made, e.g.:
P_ 0 1
P50 2
P_ 0 2
o f f
o f f
Setting:
Value of master function 1
Setting:
Value of master function 2
ENTER
ENTER
ENTER
VALUE
Menu structure with the SimpleBox
P0 - -
_ _ _ _
P1- -
P2- -
P4- -
P5- -
P6 - -
P7- -
P0 0 1
P0 0 2
P10 0
P10 1
P114
P20 0
P20 1
P220
P40 0
P40 1
P48 3
Operating value display
(or operational)
following mains ON
P3- -
P30 0
P30 1
P327
P0 0 3
To change a parameter value, the ENTER key
or
OK
must be pressed when the relevant parameter number is
displayed.
Changes can then be made using the VALUE keys
or
and must be confirmed with
OK
to save them and
leave the parameter.
As long as a changed value has not been confirmed by pressing ENTER , the value display will flash; this value
has not yet been stored in the frequency inverter.
If a change is not to be saved, the "DIRECTION" key
can be pressed to leave the parameter.