beautypg.com

KROHNE IFC 090 Converter EN User Manual

Page 74

background image

Measuring range
Current output
Tag No.

Primary head constant
Pulse output

10.5 Instrument nameplates

10/5

ALTOFLUX IFM 4080K /D/ /6
A94 9872 ISO Kl. E IP 67
DN50/2”-PFA- HC4 PN 40 Bar

Altometer

Q: 0-21.2 m

3

/h GK: 5.123

I: 0-20 mA R

i

0.5 kOhm P: 1000 p/s

Tag:

Holland

Insulation class
of field coils

Protection category
to IEC 529 / EN 60529

Flange pressure rating
or flange class

Electrode material
(see table)

Liner
(see table)

Meter size
DN in mm and
inch equivalent

Type designation

Series No.

Magnetic field frequency
(here: 1/6 of power
frequency)

Abbreviations

Liner

AL

Fused aluminium
oxide (99.7% Al

2

O

3

)

H

Hard rubber

NE

Neoprene

PFA

Teflon

®

-PFA

PUI

Irethane

T

Teflon

®

-PTFE

W

Soft rubber

ZR

Zirconium oxide

Electrode material

C

conductive rubber compound

HB 2

Hastelloy B2

HC 4

Hastelloy C4

IN

Incoloy

M4

Monel 400

Ni

Nickel

PT

Platinum

TA

Tantalum

TI

Titanium

V4A

Stainless steel 1.4571 (SS 316 Ti)

xx / TC

xx with conductive PTFE compound
(xx = base material, e.g. HC4)

Teflon

®

is a registered trademark of Du Pont

Separate signal converter in rotatable field housing

Compact flowmeters

ALTOFLUX IFC 090F /D/ /6
A96 6008

Altometer

Q: 0-150 m

3

/h GK: 2.706

I: 0-20 mA R

i

0.5 kOhm P: 1000 p/s

Tag: 98-FT-096

Holland

Measuring range
Current output
Tag No.

Primary head constant
Pulse output

Type designation

Series No.

Magnetic field frequency
(here: 1/6 of power
supply frequency)