beautypg.com

KROHNE IFC 020 Converter EN User Manual

Page 76

background image

Installation and operating instructions IFC 020

12/1

12 Block diagram – signal converter

1 Input amplifier

n overdrive-proof signal processing,

rapid and accurate

n digital signal processing and sequence

control

n patented, high-resolution A/D converter,

digitally controlled and monitored

n high signal-to-noise ratio through low-

loss field power supply

2 Field power supply

n the low-loss field power supply

generates the pulsed, electronically

controlled DC current for the magnetic

coils of the primary head

n the low-loss regulator reduces the power

take-off

n high field current causes a high signal

level.

3 Current output

n galvanically isolated from all other

groups

n converts the digital output signal from the

µ

P 3 microprocessor into a proportional

current

n HART

®

and RS 485-interfaces,

switchable

4 Binary outputs

n galvanically isolated from other groups

n selectable input/output combinations

n pulse output, passive FET optocouplers

allow connection

of electronic and electromechanical

totalizers

n status output, for limit value, error

identification, or flow direction

in forward/reverse flow mode (F/R)

5 Display/operator control unit

n large-size illuminated LC display

n 3 keys for operator control of the signal

converter

n connection to the internal IMoCom bus

6 IMoCom bus plug connector

n for connection of external control and

test devices

7 External control input (IFC 020 E only)

n reset of internal totalizer

n zero setting of all outputs

The standard

n high accuracy

n practice oriented standard equipment

n current and pule output (galvanically

isolated)

n status output, adjustable for many tasks:

indicators for trip point, flow direction and

errors.

n IMoCom-Bus suitable for many in- and

external tasks

n simple, uniform KROHNE control outline

n very lowpower consumption

n HART

®

and RS 485-interfaces