beautypg.com

KROHNE IFC 020 Converter EN User Manual

Page 61

background image

Installation and operating instructions IFC 020

8/4

Changeover of operating voltage on AC Versions 1 and 2 8.3

.

Switch off power source before opening the housing !

IFC 020 K and IFC 020 F

IFC 020 E

Refer to Sect. 8.1 for Figs. A to F.

1)

Unscrew the 4 recessed head screws

(Fig. A), and remove transparent cover.

2)

Unscrew the recessed head screw

(Fig. B) and remove the black plastic

cover.

3)

Carefully pull out the green connecting

plugs (power supply and outputs)

(Fig. C).

4)

Unscrew the 2 recessed head screws

(Fig. D) and remove the black metal

cover.

5)

Carefully pull out the blue 9-pin

plug (connection to the primary head)

(Fig. D).

6)

With a screwdriver, carefully remove

the 4 metal clips (Fig. E).

7)

Remove the electronics unit

from the housing (Fig. F) and detach the

ground conductor.

8)

Transpose voltage selector on the power

supply PCB (illustration in Sect. 8.8) to

obtain the required voltage according to

the table in Sect. 8.2.

9)

Change power fuse F1, see table in

Sect. 8.2 for fuse ratings.

10) Reassemble in reverse order,

points 7) - 1) above.

Refer to Sect. 8.1 for Figs. 1 to 3.
1)

Unscrew the 4 screws (S1),

on the front (Fig. 1).

2)

Carefully remove the plug-in unit

from the subassembly support.

3)

Unscrew the 4 recessed head screws

(S2) on the front (Fig.1).

4)

Remove the ribbon cable from the

display unit. For that pull up the

securing clamp (Fig. 3).

Note down the position of the contact

side of the ribbon connector.

5)

Unscrew the 4 recessed head screws on

the back (Fig.2) and carefully pull the

electronic unit out of the cassette,

together with the back.

6)

Transpose the voltage selector on the

power PCB (see Fig. in Sect. 8.9) for the

desired voltage according to the decal

on the transformer.

7)

Exchange power fuse F1.

Value see table in Sect. 8.2.

8)

Reassemble in reverse order,

points 5) - 1) above.