Installation and operating instructions IFC 020

IFC 020 E signal converter 7.5.2

GS 8A Operating elements and accessories

+
0

D

Switch,

Flow direction

H

Socket for H1

plug On cable M

H1

Plug of cable M

L

Power supply ON

M

Cable between

GS 8A and IFC 020E

signal converter

P

Potentiometer

"zero point"

Y

Switch,

Measuring ranges

Z

Leitung zwischen GS 8A

und IFC 020 K und

IFC 020 F Meßumformer

Electrical connection

H1

mA meter, accuracy class

0.1, Ri < 500

,

range 4-20 mA.

Electronic frequency

counter, input resistance

approx. 1 k

,

range 0-1 kHz, time basis

min. 1 second,

see connection diagrams

in Sect. 2.4.

A

a) Switch off power supply before starting work !

b) Unscrew the 4 recessed head screws (S1)

on the front plate (see Sect. 8.1, Fig. 1).

c) Carefully pull off plug-in unit from subassembly

support.

d) The electrical connection is on the X1 and X2

connectors at the rear hand side of the

IFC 020 E signal converter as shown in

connection diagram with cable M.

1,25

2,5

5

10

20

320

160

80

40

20

Y

P

D

L

H

7/6

Power supply

connection

Electrical connection

of mA meter and

electronic frequency

counter (see Sect. 2.4).

Electrical connection of IFC 020 E and GS 8A