B.55 [SOURce:]VOLTage:PROTection:OVEr COMMAND

VOLT:PROT:OVE

Syntax:

Short Form: [SOUR:]VOLT:PROT:OVE
Long Form: [SOURce:]VOLTage:PROTection:OVEr
where = overvoltage protection limit

Description: Sets overvoltage protection limit. Overvoltage protection setpoint is stored in non-volatile memory;

value is restored upon power-up.

B.56 [SOURce:]VOLTage:PROTection:OVEr? QUERY

VOLT:PROT:OVE?

Syntax:

Short Form: [SOUR:]VOLT:PROT:OVE?
Long Form: [SOURce:]VOLTage:PROTection:OVEr?
Returns = overvoltage protection limit

Description: Indicates overvoltage protection limit.

B.57 [SOURce:]VOLTage:PROTection:OVEr:STATe[:LEVel] COMMAND

VOLT:PROT:OVE:STAT

Syntax:

Short Form: [SOUR:]VOLT:PROT:OVE:STAT[:LEV]
Long Form: [SOURce:]VOLTage:PROTection:OVEr:STATe[:LEVel]
where = 1 (enabled) or 0 (disabled)

Description: Enables (1) or disables (0) the overvoltage protection level set using VOLT:PROT:OVE. This

command saves having to change the protection level to some value outside of the operating range.

B.58 [SOURce:]VOLTage:PROTection:OVEr:STATe[:LEVel]? COMMAND

VOLT:PROT:OVE:STAT?

Syntax:

Short Form: [SOUR:]VOLT:PROT:OVE:STAT[:LEV]
Long Form: [SOURce:]VOLTage:PROTection:OVEr:STATe[:LEVel]
where = 1 (enabled) or 0 (disabled)

Description: Indicates whether the overvoltage protection level set using VOLT:PROT:OVE is enabled (1) or

disabled (0).

B.59 [SOURce:]VOLTage:PROTection:UNDer COMMAND

VOLT:PROT:UND

Syntax:

Short Form: [SOUR:]VOLT:PROT:UND
Long Form: [SOURce:]VOLTage:PROTection:UNDer
where = undervoltage protection limit

Description: Sets undervoltage protection limit. Undervoltage protection setpoint is stored in non-volatile mem-

ory; value is restored upon power-up.

B.60 [SOURce:]VOLTage:PROTection:UNDer? QUERY

VOLT:PROT:UND?

Syntax:

Short Form: [SOUR:]VOLT:PROT:UND?

Long Form: [SOURce:]VOLTage:PROTection:UNDer?

Returns: = undervoltage protection limit