TABLE 1-1. MODEL PARAMETERS
Model number
Operating Limits
Overload Protection (1)
Minimum On
Resistance
Short Mode
(Ohms)
Rated
Power
(Watts)
Rated
Voltage
((Volts)
Rated Current
Max (any Mode)
(Amperes)
Power (2)
(Watts)
Voltage (3)
(Volts)
Current (2)(4)
(Amps)
EL 1K-50-100
1000
50
100
1050
52.5
105
0.008
EL 1K-200-100
1000
200
100
1050
210
105
0.014
EL 1K-400-70
1000
400
70
1050
420
73.5
0.046
EL 1K-600-30
1000
600
30
1050
630
31.5
0.017
EL 1K-50-100D
1000 (5)
50 (5)
100 (5)
1050 (5)
52.5 (5)
105 (5)
0.008 (5)
EL 1K-200-100D
1000 (5)
200 (5)
100 (5)
1050 (5)
210 (5)
105 (5)
0.014 (5)
EL 1K-400-70D
1000 (5)
400 (5)
70 (5)
1050 (5)
420 (5)
73.5 (5)
0.046 (5)
EL 1K-600-30D
1000 (5)
600 (5)
30 (5)
1050 (5)
630 (5)
31.5 (5)
0.017 (5)
EL 2K-50-200
2000
50
200
2100
52.5
210
0.004
EL 2K-200-200
2000
200
200
2100
210
210
0.007
EL 2K-400-140
2000
400
140
2100
420
147
0.023
EL 2K-600-60
2000
600
60
2100
630
63
0.083
EL 3K-50-300
3000
50
300
3150
52.5
315
0.005
EL 3K-200-300
3000
200
300
3150
210
315
0.005
EL 3K-400-210
3000
400
210
3150
420
220.5
0.015
EL 3K-600-90
3000
600
90
3150
630
94.5
0.056
EL 4K-50-500
4000
50
500
4200
52.5
525
0.002
EL 4K-200-500
4000
200
500
4200
210
525
0.003
EL 4K-400-350
4000
400
350
4200
420
367.5
0.009
EL 4K-600-150
4000
600
150
4200
630
157.5
0.033
EL 5K-50-600
5000
50
600
5250
52.5
630
0.001
EL 5K-200-600
5000
200
600
5250
210
630
0.002
EL 5K-400-420
5000
400
420
5250
420
441
0.008
EL 5K-600-200
5000
600
200
5250
630
210
0.028
NOTES:
(1)
Temperature protection: Per FET safe junction temperature.
(2)
Maximum operating power and current may be reduced if a) ambient temperature exceeds 25°C or b) operating conditions
(ambient temperature, available air flow, etc.) cause internal load temperature to exceed safe operating conditions for
FETs (temperature fault).
(3)
Maximum permissible voltage across ±LOAD terminals. This voltage should never be exceeded, regardless of load power
or load on/off states. Applied voltage must always be positive: +LOAD with respect to –LOAD.
(4)
Each FET is individually fused. A blown fuse is reported as a Fault.
(5)