Series EL electronic loads are designed for future expandability to accommodate increased
testing needs as user requirements grow. Any EL electronic load can be expanded to a full 5 kW
capability (with a commensurate increase in maximum current carrying capacity). Additionally,
the Series EL system can be expanded above the power/current limits defined in Table 1-1 by
adding additional loads. These slave loads act in concert with a master load to increase total
power dissipation (and current handling).

TABLE 1-1. MODEL PARAMETERS

Model number

Operating Limits

Overload Protection (1)

Minimum On

Resistance

Short Mode

(Ohms)

Rated

Power

(Watts)

Rated

Voltage

((Volts)

Rated Current

Max (any Mode)

(Amperes)

Power (2)

(Watts)

Voltage (3)

(Volts)

Current (2)(4)

(Amps)

EL 1K-50-100

1000

50

100

1050

52.5

105

0.008

EL 1K-200-100

1000

200

100

1050

210

105

0.014

EL 1K-400-70

1000

400

70

1050

420

73.5

0.046

EL 1K-600-30

1000

600

30

1050

630

31.5

0.017

EL 1K-50-100D

1000 (5)

50 (5)

100 (5)

1050 (5)

52.5 (5)

105 (5)

0.008 (5)

EL 1K-200-100D

1000 (5)

200 (5)

100 (5)

1050 (5)

210 (5)

105 (5)

0.014 (5)

EL 1K-400-70D

1000 (5)

400 (5)

70 (5)

1050 (5)

420 (5)

73.5 (5)

0.046 (5)

EL 1K-600-30D

1000 (5)

600 (5)

30 (5)

1050 (5)

630 (5)

31.5 (5)

0.017 (5)

EL 2K-50-200

2000

50

200

2100

52.5

210

0.004

EL 2K-200-200

2000

200

200

2100

210

210

0.007

EL 2K-400-140

2000

400

140

2100

420

147

0.023

EL 2K-600-60

2000

600

60

2100

630

63

0.083

EL 3K-50-300

3000

50

300

3150

52.5

315

0.005

EL 3K-200-300

3000

200

300

3150

210

315

0.005

EL 3K-400-210

3000

400

210

3150

420

220.5

0.015

EL 3K-600-90

3000

600

90

3150

630

94.5

0.056

EL 4K-50-500

4000

50

500

4200

52.5

525

0.002

EL 4K-200-500

4000

200

500

4200

210

525

0.003

EL 4K-400-350

4000

400

350

4200

420

367.5

0.009

EL 4K-600-150

4000

600

150

4200

630

157.5

0.033

EL 5K-50-600

5000

50

600

5250

52.5

630

0.001

EL 5K-200-600

5000

200

600

5250

210

630

0.002

EL 5K-400-420

5000

400

420

5250

420

441

0.008

EL 5K-600-200

5000

600

200

5250

630

210

0.028

NOTES:
(1)

Temperature protection: Per FET safe junction temperature.

(2)

Maximum operating power and current may be reduced if a) ambient temperature exceeds 25°C or b) operating conditions
(ambient temperature, available air flow, etc.) cause internal load temperature to exceed safe operating conditions for
FETs (temperature fault).

(3)

Maximum permissible voltage across ±LOAD terminals. This voltage should never be exceeded, regardless of load power
or load on/off states. Applied voltage must always be positive: +LOAD with respect to –LOAD.

(4)

Each FET is individually fused. A blown fuse is reported as a Fault.

(5)

Per Channel.