B.15 debug:echo command, B.16 debug:echo? query, B.17 debug:tree:display command – KEPCO EL Series Electronic Load Operator Manual P/N 243-1295 Firmware Version 3.22 through 3.41 User Manual
Page 64: B.18 debug:tree:separator command, B.19 debug:tree:separator? query, B.20 lock command, B.21 lock? query, B.22 [source:]input[:state] command, B.15, Debug
B-4
SERIES EL 062011
B.15 DEBug:ECHO COMMAND
DEB:ECHO
Syntax:
Short Form: DEB:ECHO
Long Form: DEBug:ECHO
Where: 1 or ON turns on echo, 0 or off turns off echo
Description: Causes the EL Load to return the parsed string to the user. The parsed string may not be the
complete string sent to the EL; the parsed string contains the short form mnemonic for the command.
Factory default is DEB:ECHO off.
B.16 DEBug:ECHO? QUERY
DEB:ECHO?
Syntax:
Short Form: DEB:ECHO?
Long Form: DEBug:ECHO?
Returns: 1 if echo is on, 0 if echo is off
Description: Indicates whether echo is on or off.
B.17 DEBug:TREE:DISPlay COMMAND
DEB:TREE:DISP
Syntax:
Short Form: DEB:TREE:DISP Long
Form:
DEBug:TREE:DISPlay
Description: Produces text file showing the SCPI command set accessible to the user. The text file is
arranged in columns and can be imported into a spreadsheet application such as Excel for easy view-
ing. The column separator is determined by DEB:TREE:SEP command
B.18 DEBug:TREE:SEParator COMMAND
DEB:TREE:SEP
Syntax:
Short Form: DEB:TREE:SEP
Long Form: DEBug:TREE:SEParator
where
Description: Defines the column separator used when producing a text file of the command set using
DEB:TREE:DISP command.
B.19 DEBug:TREE:SEParator? QUERY
DEB:TREE:SEP?
Syntax:
Short Form: DEB:TREE:SEP?
Long Form: DEBug:TREE:SEParator?
Returns
Description: Returns the number corresponding to the selected column separator when producing a text
file of the command set using DEB:TREE:DISP command.
B.20 LOCK COMMAND
LOCK
Syntax:
Short Form: LOCK
Long Form: LOCK
where
Description: Controls functionality of front panel controls. When set to OFF, all front panel controls are fully
functional. When set to EMER, the front panel LOAD switch can only turn the load to the off state; all
other front panel controls except for the POWER switch are disabled. When set to LOCK, all front
panel controls except for the POWER switch are disabled.
B.21 LOCK? QUERY
LOCK?
Syntax:
Short Form: LOCK?
Long Form: LOCK?
Returns:
Description: Indicates state of front panel controls.
B.22 [SOURce:]INPut[:STATe] COMMAND
INP
Syntax:
Short Form: [SOUR:]INP[:STAT]
Long Form: [SOURce:]INPut[:STATe]
where
Description: Used to engage or disengage the load from the UUT. When set to 1 the load engages at the pro-
grammed mode and corresponding setpoint value; when set to 0 the load disengages.