beautypg.com

7 viewing configuration information, 8 changing ip mode, 9 changing static ip address or subnet mask – KEPCO EL Series Electronic Load Operator Manual P/N 243-1295 Firmware Version 3.22 through 3.41 User Manual

Page 38: Viewing configuration information -4, Changing ip mode -4, Changing static ip address or subnet mask -4, R. 3.7)

background image

3-4

SERIES EL 062011

3.7

VIEWING CONFIGURATION INFORMATION

When the Mode is OFF (none of the mode LEDs are illuminated), momentarily depressing the
LOAD pushbutton (illumination changes to blinking green) allows configuration information to be
viewed. Rotating CONTROL clockwise sequences the VOLTS, AMPS and KW displays as fol-
lows (counterclockwise sequences in reverse order starting with Firmware Version).:

• Model Information (displayed as AMPS, VOLTS and KW in respective display).

• Serial Number (5n in AMPS display, serial no. in VOLTS and KW displays)

• IP Mode (0dE in VOLTS display, S7A7 (static), dHcP, AU7O (auto) or FULL in AMPS

display). Refer to PAR. B.5 for description of IP Modes. To change IP Mode from the

front panel see PAR. 3.8.

• IP Address (1st octet = left 3 digits of AMPS, 2nd octet = right digit of AMPS, left 2 digits

of VOLTS, 3rd octet = right 2 digits of VOLTS, left digit of KW, 4th octet = right 3 digits of

KW display.) To change the static IP address from the front panel, see PAR. 3.9.

• Subnet Mask (same as IP address). To change the Subnet Mask from the front panel,

see PAR. 3.9.

• GPIB address (6PIb in AMPS, Addr in VOLTS and GPIB address in KW display). To

change the GPIB address from the front panel, see PAR. 3.10.

• Firmware Version (UEr in AMPS display, Firmware Version in VOLTS display).

• back to Model.

To exit, momentarily depress LOAD pushbutton to restore OFF mode (none of the mode LEDs
are illuminated and the LOAD pushbutton illumination is steady green).

3.8

CHANGING IP MODE

When the Mode is OFF (none of the mode LEDs are illuminated), momentarily depressing the
LOAD pushbutton (illumination changes to blinking green) allows configuration information to be
viewed.

NOTE: To abort process without changing the IP Mode, momentarily depress LOAD pushbut-

ton to restore OFF mode (none of the mode LEDs are illuminated and the LOAD push-
button illumination is steady green).

1. Rotate CONTROL until AMPS display shows IP, VOLTS shows 0dE and KW shows IP Mode

currently selected

2. Momentarily depress CONTROL: the mode shown in KW display blinks.

3. Rotate CONTROL to change IP Mode: S7S7 (static), dHcP, AU70 (auto), FULL, then

momentarily depress CONTROL to return to OFF mode (none of the mode LEDs are illumi-
nated and the LOAD pushbutton illumination is steady green).

3.9

CHANGING STATIC IP ADDRESS OR SUBNET MASK

When the Mode is OFF (none of the mode LEDs are illuminated), momentarily depressing the
LOAD pushbutton (illumination changes to blinking green) allows configuration information to be
viewed.

NOTE: To abort process without changing the address or mask, momentarily depress LOAD

pushbutton to restore OFF mode (none of the mode LEDs are illuminated and the