6 specifications, Table 1-2. series el specifications, Specifications -5 – KEPCO EL Series Electronic Load Operator Manual P/N 243-1295 Firmware Version 3.22 through 3.41 User Manual
Page 15: Series el specifications -5
SERIES EL 062011
1-5
1.6
SPECIFICATIONS
Parameters unique to different models of Series EL loads are listed in Table 1-1. Specifications
common to all Series EL models are listed in Table 1-2.
TABLE 1-2. SERIES EL SPECIFICATIONS
SPECIFICATION
RATING/DESCRIPTION
CONDITION/COMMENT
MODE CHARACTERISTICS
Linearity vs. programming command
See Table 1-3
5 – 100%; accuracy is % of Full Scale value(2)
Regulation(1)
See Table 1-3
5 – 100%; regulation is % of Full Scale value(2)
Resolution (via computer control)
14 Bits
5 – 100% of Full Scale
Current readback
(Current mode)
Computer Accuracy:
±0.25%
5 – 100%; accuracy is % of Full Scale value(2)
Computer Resolution:
±15 Bits
5 – 100% of Full Scale
Parameter readback
(Current and Voltage)
Accuracy: ±0.25% (±1% for 50V models) Accuracy is % of Full Scale value(2)
Resolution:
±15 Bits
Temperature
coefficient:
100 ppm/°C
CONTROL CHARACTERISTICS
USB Interface
Uses IEEE 488.2 and SCPI
commands and queries.
Requires driver.
RS 232 Interface
Uses IEEE 488.2 and SCPI
commands and queries.
Baud rate: 38400
Parity: None
Data Bits: 8
Stop Bits: 1
Flow Control: None
GPIB Interface
Uses IEEE 488.2 and SCPI
commands and queries.
GPIB address 10 = default
Ethernet Interface
Uses IEEE 488.2 and SCPI
commands and queries.
Optional
GENERAL CHARACTERISTICS
a-c Line Power Input
120 VAC ±10%, 50/60 Hz or
240 VAC ±10%, 50/60 Hz
120V is factory default; 240V requires internal
configuration (see PAR 2.3.1)
Cooling
Forced Air (400 CFM)
Variable speed fans, cooling determined by load
demand.
Operating Tempera-
ture
0°C to 40°C
Dimensions (load)
19”W x 7”H x 24.5”D
See Figure 2-10.
Weight (load)
88 lbs.
Storage Requirements
–20 to +60°C, 15 to 80% RH
Relatively dust free environment
NOTE:
(1) Regulation specified after 15 minutes of operation at set power level.
(2) Accuracy and regulation are valid from 5% to 100% of the rated value. The accuracy (e.g., ±0.25% of a constant current setpoint)
is ±0.25% of the full scale value and not the setpoint.