HT instruments SIRIUS89N User Manual
Page 76

SIRIUS89N
EN - 74
8.4.2. "METER" mode
In this mode the instrument shows the below screens according to the settings made as
per paragraph 8.1.
27.09.00 17:35:12
VOLTAGE
SINGLE PHASE
V1 = 230.2 V
Vpk1 = 325.5 V
ThdV = 0.0 %
Freq = 50.0 Hz
HARM. WAVE PG- PG+
Example of screen
The symbols used are described in Tab.1
For eventual messages displayed see Appendix 1 – MESSAGES DISPLAYED.
Following keys are enabled:
F1:
to pass to "HARMONIC" mode (see paragraph 8.4.3).
F2:
to pass to "WAVE" mode (see paragraph 8.4.4).
F3/F4:
to pass to previous/next function respectively.
SAVE:
to save in the instrument memory a record of “Smp” type (see
paragraph 9.2) containing the instantaneous values of voltage and
current present on the instrument inputs. This function is disabled
during a recording.
ENTER/HOLD: to enable/disable the HOLD function (updating interruption) of the
displayed data. All the previous functions remain however available.
When the HOLD function is enabled, the word
HOLD
is displayed.
When this function is enabled it’s not possible to record or take an
energy measurement. This function is disabled during a recording or
an energy measurement.
MENU:
to enter in the
MENU mode and change the instrument settings (see
paragraph 8.1 and 8.2). It’s not possible to enter the configuration
MENU during a recording or an energy measurement.
START/STOP: to
record
the
selected parameters according to the instrument’s
settings (see chapter 10).