:TRIGger:REJect

Set

Query

Description

Selects the trigger rejection filter.
Same as: Trigger key → F4 → F3

Syntax

< Long >

< Short >

:trigger:reject
:trigger:reject?

:trig:rej
:trig:rej?

Parameter

Rejection filter

0

off

1

LF

2

HF

Note

Before using this command, select the edge or
pulse trigger. See the example below.

Example

:trigger:type 0
:trigger:reject 1

Selects the edge trigger
and LF rejection filter

:TRIGger:SLOP

Set

Query

Description

Selects the trigger slope.
Same as: Trigger key → F4 → F1

Syntax

< Long >

< Short >

:trigger:slop
:trigger:slop?

:trig:slop
:trig:slop?

Parameter

Trigger slope

0

+ (positive)

1

– (negative)

Note

Before using this command, select the edge or
pulse trigger. See the example below.