beautypg.com

Data log commands, Datalog:state, Datalog:source – GW Instek GDS-1000-U Series Programming Manual User Manual

Page 50

background image

GDS-1000-U Programming Manual

50

Data Log Commands

:DATALOG:STATE ....................................................... 50

:DATALOG:SOURce .................................................... 50

:DATALOG:SAVe ......................................................... 51

:DATALOG:INTerval .................................................... 51

:DATALOG:DURation .................................................. 51

:DATALOG:STATE

Set

Query

Description

Turns the datalogging function on/off.
Same as: Utility key → More (F5) →Data Logging
Menu(F3)→Data Logging (F1).

Syntax

< Long >

< Short >

:DATALOG:STATE {0|1}
:DATALOG:STATE?

:DATALOG:STATE
{0|1}
:DATALOG:STATE?

Parameter/
Return parameter

0

Off. Stop data logging function.

1

On. Start data logging function.

Example

:DATALOG:STATE 1

Turn data logging on.

:DATALOG:SOURce

Set

Query

Description

Sets or queries the data logging source channel.

Syntax

< Long >

< Short >

:DATALOG:SOURce{1|2}
:DATALOG:SOURce?

:DATALOG:SOUR{1|2}
:DATALOG:SOUR?

Parameter/
Return parameter

1

Sets CH1 as the source channel

2

Sets CH2 as the source channel

Example

:DATALOG:SOUR 1

Set source as CH1.