beautypg.com

Trigger count – GW Instek GLA-1000 Series User Manual User Manual

Page 54

background image

GLA User Manual

54

Trigger Count

Toolbar icon

Sets the number of times GLA skips triggering condition. Setting
is available in pull-down (1, 2, 3, 4, 5, 10, 15, 20) or direct entering.

Example

GLA starts capturing data at the first
triggering condition (default).

GLA starts capturing data at the fifth
triggering condition.

You can directly type in any number, up to
65,535.

Trigger Delay
dialogue window

Select the Trigger Delay tab in the Trigger Properties dialogue.

Trigger Page

Toolbar icon

This function sets the length of skipped waveform (in data

memory blocks) after the triggering condition. Setting is available
in pull-down (1, 2, 3, 4, 5, 10, 15) or direct entering.

Waveform data in a single page = Sampling RAM size
(for RAM size setting, see page41)

Maximum trigger page for different RAM size

RAM size

GLA-1016

GLA-1032

GLA-1132

2Kbit

8192

8192

8192

16Kbit

1024

1024

1024

32Kbit

512

512

512