Specification (cont.) – GW Instek GLA-1000 Series User Manual User Manual
Page 108
![background image](/manuals/367283/108/background.png)
GLA User Manual
108
Specification (cont.)
The specifications apply under the following conditions: GLA is powered on for at least 30
minutes, within +20°C~+30°C.
GLA-1016
GLA-1032
GLA-1132
Enable
Channel
16
32
32
Enable
Condition
Don’t care,
Low, High
Don’t care,
Low, High
Don’t care,
Low, High
Enable Delay
1 ~ 65535ms
1 ~ 65535ms
1 ~ 65535ms
Data
Skew
<1.5ns
<1.5ns
<1.5ns
Compression
Channels
16
24
24
Compression
Ratio
Maximum 255
Maximum 255
Maximum 255
Signal
Statistics
Positive/
Negative,
Full cycle
within length
condition
Positive/
Negative,
Full cycle
within length
condition
Positive/
Negative,
Full cycle
within length
condition
Protocol
Analyzer
I2C, RS-232C
I2C, RS-232C
I2C, RS-232C
Current
Consumption
Static
Maximum
200mA
Maximum
200mA
Maximum
200mA
Working
Maximum
400mA
Maximum
400mA
Maximum
400mA
Power
dissipation
Static
Maximum 1W
Maximum 1W
Maximum 1W
Working
Maximum 2W
Maximum 2W
Maximum 2W
Power
Interface
USB
USB
USB
Working
voltage
4.5V ~ 5.5V
4.5V ~ 5.5V
4.5V ~ 5.5V
Temperature
Operating
0°C ~ 50°C
0°C ~ 50°C
0°C ~ 50°C
Storage
−40°C ~ 80°C
−40°C ~ 80°C
−40°C ~ 80°C