5.7.3 Adjust Application Rate

5.7.4 Shank Pressure

The meter rate can be quickly adjusted while seeding by pressing the

Meter

Rate key. This brings up the meter rate setting screen.

The hydraulic down pressure applied to the opener shanks is controlled by a
closed loop system that allows you to enter the desired pressure. The operator
can enter the amount of down pressure applied on the monitor. The monitor
controls a down pressure valve that maintains the pressure setting on the open-
er shanks through the control module. A pressure sensor measures the actual
hydraulic pressure and feeds it back to the control module. The control module
adjusts the down pressure valve to maintain the system setting. As the openers
move up and down with the terrain constant force is applied to all equally.

1. Select the meter rate to adjust turning the Toggle knob to highlight the
meter desired. Meter 1 is the default meter.

2. Press the Up/Down keys to incrementally adjust the application rate. The
rate will immediately adjust for the selected meter. To adjust another meter
navigate to it with the

Toggle knob and adjust it up or down.

The

Soft Keys will show all active meters. Pressing the Soft Key for a meter

will turn them on and off individually.

Press the

Meter Rate key again to return to the main operating screen.