5.5.3 Clear Field Acres
5.5.4 Rate Controller Meter Setup
This selection allows the operator to enter setup information for the meters.
The default screen is Meter 1. Other meters can be selected by pressing the
soft key for the desired meter.
1. Pulses per Rev: This is the num-
ber of pulses generated by the meter
sensor per 1 revolution of the meter
roller. This value is set by default but
can be manually entered. The default
value for a hydraulic drive system is
60.31 pulses per revolution.
2. Low alarm point: This is the minimum meter rpm speed the meter can
turn before the “low meter rpm” or “meter stopped” alarms will display. The
default value is 0.5 rpm.
3. Weight/Rev: This value is determined by the Meter calibration procedure or
it can be manually entered.
1. Move monitor to Aircart and
power up
2. Select Meter Calibration
3. Select desired meter to calibrate
4. Prime roller
5. Calibrate Meter
6. Enter weight of product
Loup III Quick Start Calibration
Choosing this item allows the user to clear the accumulated field acres.
NOTE: If total acres cannot
be cleared from the settings
menu. Contact your Seed
Hawk Dealer for information
on clearing the total acres
register.
NOTE: Once verified the
field acres cannot be re-
stored.
1. Using the Selector Knob, high-
light "Clear Field Acres"
2. A dialog box will appear verifying
your selection. Verify by pressing the