2014 30 SERIES OPERATOR’S MANUAL – DOMESTIC 47

5.5.1 Pre-Calibration Setup

5.5 Meter Calibration

All meters must be individually calibrated. Calibrations must be done each time
a crop is changed. Calibration for the seed is done at the front hopper, on the
left side of the machine, and calibration for the fertilizer is done at the rear
hopper, on the right side of the machine. Measure and record the weight of the
empty calibration bag supplied.

1. Measure and record the weight of the empty calibration bag supplied.

Calibration Bag Weight: _________________

Once calibration bag is weighed, then attach the bag to the meter

5.5.2 Loup III Calibration Procedure

1. Select "Meter Calibration" from the
Menu Settings.

2. Select the desired meter to
calibrate.

NOTE: It is important to

calibrate as close to the ac-

tual seeding rpm of the roller

as possible. Refer to Section

11.0 for the Seeding Table

to get an approximate roller

rpm for the specific roller 

and drill width.