beautypg.com

2 tractor hook up – Seed Hawk 30 SERIES 2014 User Manual

Page 28

background image

SEED HAWK

®

2014 30 SERIES OPERATOR’S MANUAL – DOMESTIC

22

IMPORTANT! DO NOT plug this line during storage. Damage to the gauges
and manifold may occur.

4.2 Tractor Hook up

Connect the ¾” (19mm) hydraulic line to activate the opener lift/lower. The
opener lift/lower line is marked with a wide red band. The opener lock-up ball
valves must be open in order to lower the shanks. Both the opener line and
lock-up ball valves are located at the hydraulic manifold.

It is very important that the hydraulic fluid dump (yellow band) lines return
UNRESTRICTED back to the tractor hydraulic reservoir. There are male and
female pioneer quick couplers with the balls removed supplied with the Seed
Hawk. Be sure to use these sets of couplers for the case drains.

Any alterations or restrictions in this line will cause damage to the
implement that will NOT be covered by warranty.

Always connect the case drain line (yellow band) to return hydraulic fluid back 
to the tractor reservoir. The case drain line is a ¾” (19mm) line from the
hydraulic manifold. The case drain line(s) MUST return to the tractor UNRE-
STRICTED. Failure to do so can cause damage to the hydraulic cylinders or fan
motor and will void Manufacturer’s Warranty. The case drain(s) must be con-
nected even when lowering the wings. Seed Hawk

®

recommends that the case

drain(s) have their own port into the tractor’s reservoir.

Connect the other pair of ½” hydraulic lines to activate the wing lift and lower
(green band), and the standby supply to the wing cylinders. The manifold supply
line is marked with a narrow green band, and the return line is marked with
a wide green band. This tractor lever is locked in full pressure position while
seeding.

4.2.1 Opener Lift & Lower

4.2.2 Wing Up & Down

4.2.3 Case Drain(s)

NOTE: Do not TEE the man-

ifold and case drain dump

lines together, unless the

junction is placed right at the

tractor reservoir.

NOTE: Some newer tractors

cannot return to the hydrau-

lic reservoir. Refer to specific 

tractor Operator's Manual

and/or consult your dealer

for tractor requirements

NOTE: DO NOT plug the

case drain line during storage;

damage to the gauges and

manifold may occur.