THERMAL BALANCER

Figure 4 shows the internal wiring of the thermal balancer. The

device may be tested after disconnecting the four leads from their

respective terminals on the unit.

1. Apply a test light to the yellow and red leads.

• The lamp should light as the contact in this circuit is normally

closed when the resistor is cool.

2. Apply a light to the black and yellow leads.

• The lamp should not light as the contact in this circuit is normally

open when the resistor is cool.

3. Remove the test light.

4. Apply 120 volts to the white and red leads which power the 1900

ohm resistor. After a warming period the contacts of the thermal

balancer should operate.

5. Remove the test light.

6. Apply the test light as described in steps 1 and 2.

While the resistor is still warm the lamp indications should be the

opposite as described previously.

FIGURE 4.

MANUAL RESET HIGH LIMIT

This boiler is equipped with a manual reset high limit switch,

located under the small cover on the side of the jacket, see

Figure 5. This device provides positive shutdown of the

boiler in the event of boiler or system malfunction. Should the

surface temperature of the copper tubing heat exchanger

reach 250°F (120°C), the high limit switch will activate,

the gas valve will close, the pilot and main burners will be

extinguished. If the high limit switch should shut off unit, check

the following conditions:

• No water in boiler.

• Restricted water flow through the boiler.

• Improper wiring (boiler firing without circulator

operating).

• Pump failure.

After correcting failure condition remove the protector switch cover

and push the reset button. The high limit switch may be reset after

the coil surface cools to 6°F (3.3°C) below the trip setting.

HIGH LIMIT SWITCH

FIGURE 5.

SAFETY FLOW SWITCH

The safety flow switch is a safety device which must be installed at

the water outlet of the unit to prevent main burner operation in the

event of inadequate water flow through the unit.

An accessory package containing a safety flow switch is available

for this application.

This switch may be mounted in a horizontal pipe line or a vertical

pipe line with upward water flow. Do not install the switch where the

water flow is downward.

For proper performance mount the switch in a section of pipe where

there is a straight run of at least 5 pipe diameters on each side of the flow

switch (i.e. do not locate adjacent to valves, elbows, orifices, etc.).

The flow switch shall be mounted in a standard 1-1/2" x 1-1/2" x 1"

tee for a 1-1/2" pipe application. For larger pipe sizes use a reducing

tee in order to keep the switch as close to the pipe as possible. Install

the flow switch in the branch (top) opening of the reducing tee and

provide adequate paddle length in the flow stream. For example in

a 2" pipe installation use a 2" x 2" x 1" reducing tee. For 2", or 3"

pipe use paddle segments as supplied. For other pipe sizes (i.e.

1-1/4", 1-1/2" and 2-1/2") trim the paddle to the proper pipe size, see

Figure 6 on page 10. If a standard tee is used, install a face or hex

bushing in the top opening. The paddle must be adjusted or trimmed

to the size of the pipe in which it will be installed.

CAUTION

Any part of the paddle must not touch the pipe or any restrictions in

the pipe. Screw the flow switch in position so the flat of the paddle

is at right angles to the flow. The arrow on the side case must point

in the direction of the flow.

TABLE 3 - SAFETY FLOW SWITCH

Minimum Pipe Rate

Model Number

Contacts Closed

(Flow)

Contacts Open

(No Flow)

GPM

LPM

GPM

LPM

HW-300

5.8

22.0

3.7

14.0

HW-399

7.5

28.4

5.0

18.9

HW-420

7.5

28.4

5.0

18.9

HW-520

13.7

51.9

9.5

36.0

HW-610/670

13.7

51.9

9.5

36.0

The safety flow switch may be field adjusted to obtain higher

minimum flow rates than those shown in table 3.