FOR YOUR SAFETY READ BEFORE OPERATING

WARNING:

FLAMMABLE

If you do not follow these instructions exactly, a

fire or explosion may result causing property damage, personal

injury or loss of life.

A.

B.

THIS APPLIANCE IS EQUIPPED WITH AN IGNITION

DEVICE WHICH AUTOMATICALLY LIGHTS THE PILOT.

DO NOT TRY TO LIGHT THE PILOT BY HAND.

C.USE ONLY YOUR HAND TO TURN THE GAS CONTROL

KNOB. NEVER USE TOOLS. IF THE KNOB WILL NOT

TURN BY HAND, DON’T TRY TO REPAIR IT. CALL A

QUALIFIED SERVICE TECHNICIAN. FORCE OR

ATTEMPTED REPAIR MAY RESULT IN A FIRE OR

EXPLOSION.

D.DO NOT USE THIS APPLIANCE IF ANY PART HAS BEEN

UNDER WATER. IMMEDIATELY CALL A QUALIFIED

SERVICE TECHNICIAN TO INSPECT THE APPLIANCE

AND TO REPLACE ANY PART OF THE CONTROL

SYSTEM AND ANY GAS CONTROL WHICH HAS BEEN

UNDER WATER.

E. DO NOT OPERATE APPLIANCE UNLESS UNIT IS FILLED

WITH WATER AND INLET LINES ARE FULLY OPEN.

BEFORE LIGHTING: SMELL ALL AROUND THE

APPLIANCE AREA FOR GAS. BE SURE TO SMELL

NEXT TO THE FLOOR BECAUSE SOME GAS IS HEAVIER

THAN AIR AND WILL SETTLE ON THE FLOOR.

WHAT TO DO IF YOU SMELL GAS

DO NOT TRY TO LIGHT ANY APPLIANCE.
DO NOT TOUCH ANY ELECTRIC SWITCH.
DO NOT USE ANY PHONE IN YOUR BUILDING.

IMMEDIATELY CALL YOUR GAS SUPPLIER FROM

A NEIGHBOR’S PHONE. FOLLOW THE GAS

SUPPLIER’S INSTRUCTIONS.

IF YOU CANNOT REACH YOUR GAS

SUPPLIER, CALL THE FIRE DEPARTMENT.

FIGURE “C”

PILOT

PILOT FIRING VALVE

HANDLE “OFF”

POSITION

FIGURE “D”

PILOT

HANDLE “ON”

POSITION

FLOW

FLOW

FIGURE “C”

FIGURE “D”

HANDLE “OFF”

POSITION

MANUAL SHUTOFF VALVE

HANDLE “ON”

POSITION

ON

OFF

"OFF" POSITION

FIGURE "A"

ON

OFF

"ON" POSITION

FIGURE "B"

GAS VALVE

CONTROL KNOB

HONEYWELL GAS VALVE

OPERATING INSTRUCTIONS

TO TURN OFF GAS TO

APPLIANCE

MAIN BURNER

PILOT BURNER

1. T URN OFF ALL ELECTRICAL POWER T O APPLIANCE.

2. T URN T OP KNOB OF GAS CONTRO L VALVE CLOCKWISE TO “OFF”. (FIG. “A”)

3. T URN MAIN FIRING VALVE COUNTER CLOCKWISE TO “OFF” (FIG. C), A ND

T URN PILO T FIRING VALVE COUNTERCLOCKWISE T O “OFF” (FIG “E”).

4. SET T HE THERMOSTAT TO LOWWEST SETTING.

1.

STOP! READ THE SAFETY INFORMATION

ABOVE ON THIS LABEL.

6. TURN MANUAL SHUTOFF VALVE COUNTERCLOCK-

WISE TO “OFF” (FIG C). TURN PILOT MANUAL VALVE

COUNTERCLOCKWISE TO “OFF” (FIG E).

9. TURN PILOT FIRING VALVE CLOCKWISE TO “ON”

(FIG F).

2. SET THE THERMOSTAT TO LOWEST SETTING.

8. TURN TOP KNOB OF GAS CONTROL COUNTER-

CLOCKWISE TO “ON” (FIG B).

3. TURN OFF ALL ELECTRIC POWER TO THE

APPLIANCE.

11. SET THERMOSTAT TO DESIRED SETTING. PILOT

BURNER WILL BE IGNITED BY ELECTRONIC SPARK.
12. LOCATE PEEP HOLE IN FRONT OF THE PILOT

BURNER. MAKE SURE PILOT IS BURNING.

13. WITH PILOT FLAME ESTABLISHED, TURN MANUAL

SHUT OFF VALVE CLOCKWISE TO “ON” (FIG D),

TO ALLOW GAS TO REACH MAIN BURNER. NOTE:

ADVISORY: IF MAIN BURNER FAILS TO IGNITE, MAKE

SURE PILOT IS BURNING. IF THE APPLIANCE WILL

NOT OPERATE, FOLLOW THE INSTRUCTIONS BELOW

ON THIS LABEL “TO TURN OFF GAS TO APPLIANCE”

AND CALL YOUR SERVICE TECHNICIAN OR GAS

SUPPLIER.

ADVISORY: THERE IS A FIFTEEN (15) SECOND TRIAL

PERIOD FOR PILOT IGNITION WHICH IS TIME ENOUGH

FOR IGNITION WHEN AIR HAS BEEN BLED FROM GAS

LINES PRIOR TO IGNITIION ATTEMPT. IF PILOT FAILS

TO IGNITE AND YOU SUSPECT THAT IT IS DUE TO AIR

IN THE LINES, CLOSE PILOT MANUAL VALVE AND

REPEAT LIGHTING PROCEDURE STEPS 1 THRU 12

4. THIS APPLIANCE IS EQUIPPED WITH AN IGNITION

DEVICE WHICH AUTOMATICALLY LIGHTS THE

PILOT. DO NOT TRY TO LIGHT THE PILOT BY HAND.
5. REFER TO DIAGRAMS ABOVE. TURN TOP KNOB OF

GAS CONTROL CLOCKWISE , TO "OFF"

POSITION (FIG. A)

7. WAIT FIVE (5) MINUTES TO CLEAR OUT ANY GAS.

THEN SMELL FOR GAS, INCLUDING NEAR THE

FLOOR. IF YOU SMELL GAS, STOP! FOLLOW

210135-000 REV 02

THE REDUNDANT MAIN COMBINATION VALVE WILL

ALREADY BE OPEN, AND MAIN BURNER WILL IGNITE.

"B" IN THE SAFETY INFORMATION ABOVE ON THIS

LABEL. IF YOU DON'T SMELL GAS, GO TO THE NEXT STEP

10. TURN ON ALL ELECTRIC POWER TO THE APPLIANCE

LIGHTING AND OPERATING INSTRUCTIONS (NATURAL AND PROPANE GAS WITH I.I.D.)