Table 13.

Lockout Models B, H, D and J Only - Green LED Status Codes

Green LED

Flash Code

(X+Y)

a

Indicates

Next System Action

Recommended Service Action

OFF

No "Call for Heat"

not applicable

none

Flash Fast

Startup - Flame sense calibration

not applicable

none

Heartbeat

Normal operation

not applicable

none

3

Recycle

- Flame failed during run

Initiate new trial for ignition. Flash

code will remain through the ignition

trial until flame is proved.

If system fails to light on next trial

for ignition, check gas supply,

pilot burner, flame sense wiring,

contamination of flame rod, burner

ground connection.

4

Flame sensed out of sequence

If situation self corrects within 10

seconds, control returns to normal

sequence. If flame out of sequence

remains longer than 10 seconds,

control goes to Flash code 6+4 (see

below).

Check for pilot flame. Replace gas

valve if pilot flame is present. If no

pilot flame, cycle "Call for Heat." If

error repeats, replace control.

7

Flame sense leakage to ground

Control remains in wait mode. When

the fault corrects, control resumes

normal operation after a one minute

delay.

Check flame sense lead wire for

damage or shorting. Check that

flame rod is in proper position.

Check flame rod ceramic for cracks,

damage or tracking.

8

Low secondary voltage supply-

(below 15.5 Vac)

Control remains in wait mode. When

the fault corrects, control resumes

normal operation after a one minute

delay.

Check transformer and AC line for

proper input voltage to the control.

Check with full system load on the

transformer.

6+2

Failed trial for ignition resulting in

lockout

Remain in lockout until "Call for

Heat" is cycled.

Check gas supply line, pilot burner,

spark and flame sense wiring, flame

rod contaminated or out of position,

burner ground connection.

6+3

More than 5 flame failures during run

on the same "Call for Heat" resulting

in lockout

Remain in lockout until "Call for

Heat" is cycled.

Check gas supply, pilot burner, flame

sense wiring, contamination of flame

rod, burner ground connection.

6+4

Flame sensed out of sequence-

longer than 10 seconds

Control waits until flame is no

longer sensed and then goes to

soft lockout. Flash code continues.

Control auto resets from soft lockout

after one hour.

Check for pilot flame. Replace gas

valve if pilot flame present. If no pilot

flame, cycle "Call for Heat." If error

repeats, replace control.

ON

Soft lockout due to error detected

during self check sequences

Control auto resets from soft lockout

after one hour.

Reset by cycling "Call for Heat." If

error repeats, replace the control.

a

Flash Code Descriptions:

- Flash Fast: rapid blinking.

- Heartbeat: Constant 1/2 second bright 1/2 second dim cycles.

- A single flash code number signifies that the LED flashes X times at 2Hz, remains off for two seconds, and then repeats the

sequence.

- X+Y flash codes signify that the LED flashes X times at 2Hz, remains off for two seconds, flashes Y times at 2Hz, remains off for three

seconds, and then repeats the sequence.