beautypg.com

For your safety read before lighting, Lighting instructions, Warning – A.O. Smith HW 610 User Manual

Page 43

background image

43

FOR YOUR SAFETY READ BEFORE LIGHTING

WARNING:

FLAMMABLE

If you do not follow these instructions exactly, a

fire or explosion may result causing property damage, personal

injury or loss of life.

C.

D.

WHAT TO DO IF YOU SMELL GAS

DO NOT TRY TO LIGHT ANY

APPLIANCE.

DO NOT TOUCH ANY ELECTRIC SWITCH;

DO NOT USE ANY PHONE IN YOUR BUILDING

IMMEDIATELY CALL YOUR GAS SUPPLIER FROM

A NEIGHBOR'S PHONE. FOLLOW THE GAS

SUPPLIER'S INSTRUCTIONS.

IF YOU CANNOT REACH YOUR GAS SUPPLIER,

CALL THE FIRE DEPARTMENT.

WARNING: HOT WATER CAN PRODUCE

3rd DEGREE BURNS IN 6 SECONDS AT

140

O

F. (60

O

C).

IN CASE OF POWER FAILURE DO NOT ATTEMPT

TO OPERATE APPLIANCE. IMPROPER INSTALLATION,

ADJUSTMENT, ALTERATION, SERVICE OR MAINTENANCE

CAN CAUSE PROPERTY DAMAGE, PERSONAL INJURY

OR LOSS OF LIFE. REFER TO THE USER'S

INFORMATION MANUAL PROVIDED WITH THIS

APPLIANCE. INSTALLATION AND SERVICE MUST BE

PERFORMED BY A QUALIFIED INSTALLER, SERVICE

AGENCY OR THE GAS SUPPLIER.

THIS APPLIANCE IS EQUIPPED WITH AN IGNITION

DEVICE WHICH AUTOMATICALLY LIGHTS THE PILOT.

DO NOT TRY TO LIGHT THE PILOT BY HAND.

BEFORE OPERATING: SMELL ALL AROUND THE APPLI-

ANCE AREA FOR GAS. BE SURE TO SMELL NEXT TO

THE FLOOR BECAUSE SOME GAS IS HEAVIER THAN

AIR AND WILL SETTLE ON THE FLOOR.

USE ONLY

YOUR HAND TO TURN THE GAS

CONTROL KNOB. NEVER USE TOOLS. IF THE

KNOB WILL NOT TURN BY HAND, DON'T TRY

TO REPAIR IT. CALL A QUALIFIED SERVICE

TECHNICIAN. FORCE OR ATTEMPTED

REPAIR MAY RESULT IN A FIRE OR EXPLOSION.

DO NOT USE THIS APPLIANCE IF ANY PART

HAS BEEN UNDER WATER. IMMEDIATELY CALL

A QUALIFIED SERVICE TECHNICIAN TO

INSPECT THE APPLIANCE AND TO REPLACE

ANY PART OF THE CONTROL SYSTEM AND ANY

GAS CONTROL WHICH HAS BEEN UNDER WATER.

ON

OFF

"OFF" POSITION

FIGURE "A"

ON

OFF

"ON" POSITION

FIGURE "B"

GAS VALVE

CONTROL KNOB

HONEYWELL GAS VALVE

A.

B.

FIGURE “C”

PILOT

PILOT FIRING VALVE

HANDLE “OFF”

POSITION

FIGURE “D”

PILOT

HANDLE “ON”

POSITION

LIGHTING INSTRUCTIONS

A.

C.

TO TURN OFF GAS TO

APPLIANCE

S E T T H E S Y S T E M C O N T R O L L E R TO T H E

L O W E S T S E T T I N G .

B. T U R N O F F E L E C T R I C A L P O W E R

TO A P P L I A N C E .

TURN TOP KNOB OF GAS CONTROL VALVE

CLOCKWISE TO "OFF" POSITION SEE, (FIG. A).

CLOSE FIRING AND PILOT MANUAL VALVES,

CLOCKWISE . SEE ABOVE.

211686-000 REV. XX

1. STOP! READ THE SAFETY INFORMATION

ABOVE ON THIS LABEL.

7. TURN TOP KNOB OF GAS CONTROL COUNTER-

CLOCKWISE TO "ON" (FIG. B). OPEN PILOT

MANUAL VALVES, COUNTER-CLOCKWISE .

8. TURN ON ALL ELECTRIC POWER TO THE

APPLIANCE.

FIGURE “D”

9. SET SYSTEM TEMPERATURE CONTROLLER

TO DESIRED SETTING.

10. WHEN CONTROLLER CALLS FOR HEAT, THE

CIRCULATING PUMP WILL OPERATE AND THE

PILOT BURNER WILL BE SPARK IGNITED. GAS

CONTROL WILL OPEN AND MAIN BURNER WILL

THEN IGNITE. NOTE: IF PILOT FAILS TO IGNITE,

TURN OFF APPLIANCE AND CONSULT YOUR

"INSTALLATION AND USER'S MANUAL" FOR

ADJUSTMENTS AND TROUBLE SHOOTING.
11. IF THE APPLIANCE WILL NOT OPERATE, FOLLOW

THE INSTRUCTIONS "TO TURN OFF GAS TO

APPLIANCE" AND CALL YOUR SERVICE

TECHNICIAN OR GAS SUPPLIER.

2. MAKE SURE BOILER AND SYSTEM ARE FILLED

WITH WATER AND ALL AIR HAS BEEN EXPELLED

FROM APPLIANCE.

3. TURN OFF ALL ELECTRIC POWER TO THE

APPLIANCE. SET SYSTEM TEMPERATURE

CONTROLLER TO LOWEST SETTING. PURGE ALL

GAS LINES OF AIR.

4. DO NOT ATTEMPT TO LIGHT THE PILOT BY HAND
5. REFER TO DIAGRAMS ABOVE. TURN TOP KNOB OF

GAS CONTROL & PILOT VALVE (FIG. “C”)

CLOCKWISE , TO "OFF" POSITION (FIG. “A”)

6. WAIT FIVE (5) MINUTES TO CLEAR OUT

ANY GAS. THEN SMELL FOR GAS, INCLUDING

NEAR THE FLOOR. IF YOU SMELL GAS,

STOP! FOLLOW "B" IN THE SAFETY

INFORMATION ABOVE ON THIS LABEL. IF YOU
DON'T SMELL GAS, GO TO THE NEXT STEP.

LIGHTING AND OPERATING INSTRUCTIONS NATURAL AND PROPANE FOR HW300 - HW399