Warning, Inset b, Inset c inset b – Hired-Hand Evolution Series 3000/3001 User Manual
Page 52: Inset c, Inset a pcb – 167 power ventilation, Unit #1 vents, Powertrak, Powertrak inset c, Open close com, Wire for either fail-safe or normal action

Part No. 4801-5307 Rev 2-10
Evolution 3000 and 3001
52 of 70
9.11 Connecting the PowerTrak and S-3 Back-Up to the Evolution
3000 & 3001
WARNING!
• Keep High Voltage (Or AC) Separate
From Low Voltage Wires!
• Do not perform modifications or wiring
with voltage applied!
!
Inset B
S-3 Vent
Override
for
Fail-Safe
Action
INLET
MODE
Vent Override
Cool 1
Tunnel Override
Cool 3
Vents & Tunnel Will Wire The Same
PowerTrak
Inset C
Inset B
S-3 Vent
Override
for
Normal
Action
NOTE:
Refer to the
S-3 Manual
4801-2997 for
additional P5
& P6
S-3 Setting
Instructions
PowerTrak
Inset C
PowerTrak
Inset C
Evolution 3000 / 3001
Inset A
PCB – 167 Power Ventilation
J1
J2
Hired - Hand
B. Crider
D 1
D 2
D 3
D 4
Copyright (c) 2000
PCB 167 Rev ‘0’
COM
Ope
n
Cl
os
e
Un
it #
1 (
Ve
nts
)
COM
Op
en
Cl
os
e
Uni
t #
2 (
Tunnel
)
+12V
Open
U1
Relay Control
Close
U1
Open
U2
Close
U2
HIRED-HAND
RLY 1
RLY
2
RLY 3
RLY 4
NOTE: If curtain is setup to pull curtain up to open, then reverse wires connected to "OPEN" and "CLOSE" terminals.
NOTE: Only 1 Power Trak can be connected to each Power Trak outlet. If Additional Power Traks are needed,
Then use of relay boxes is necessary to separate the load.
NOTE: All PowerTrak units will connect the same.
To
EV-3000/3001
PCB 167
To
EV-3000/3001
PCB 167
Unit #1 Vents
Open
Close
Com
To
EV
S-3
Wire for
Either
Fail-Safe
OR
Normal
Action
NOTE:
If connecting the Back-Up
to a relay box instead of
PowerTrak, Cut and
discard the specific two or
four components shown as
needed.
Secondary Sensing System
Tunnel Override
Inset B
Vent Override
}
EV-3000/3001
PCB 167