Part No. 4801-5307 Rev 2-10

Evolution 3000 and 3001

10 of 70

** PASSWORD PROTECTED **

You must enter the current controller
Password to continue.
Press the ENTER button to proceed.

Password: XXXX

5.5 Status

Display

The following is an example of Main Display screen displaying the standard Target Conditions status
screen. The Main Display screen displays both status and programming screens.










5.6 Stage

Switch

The stage LED indicator lights when a stage is active. The stage switch is used to select Auto operation,
On, or Off. If switch is in Auto position, the stage operation is controlled by the controller. That is, the
stage may turn on and off according to settings selected from the Main Display screen. If switch is in the
On position, a stage is On continuously. If switch is in the Off position, a stage is Off with the exception
of Back-Up conditions.

The white space is used to affix a label indicating stage function (i.e. brooder, fan, light, cool, etc.)

NOTE: Stages 1-16 are marked on Main panel. For optional stages 17-64, use stick-on label to number
stages.















5.7 Locks

A lock feature has been included for additional
security to the Evolution 3000 and 3001 settings
with software versions V0.16 and higher. This
feature locks the Program Setup screens to
prevent changes. Locked screens are noted by a
lock symbol ( ) in the upper right of the
screen. The Target Conditions and Minimum
Vent screens are not lockable. When the lock
feature is disabled ( ), all screens will show
unlocked until the password is changed. See
Section 7.13.

NOTE: The Diagnostics screen can only be unlocked using the HHI Service Code; Contact your local

dealer for assistance.

1

1

Stage number

(Use labels to denote

stages 17-64)

ON, OFF, AUTO
Switch positions

Stick Icon label onto
white area or use for
notation

LED Indicator (lights

when stage is ON)

Icon labels are provided to
affix to white area of stage
control. Icon symbols are
shown at right.

Heater

Negative Fan

Light

Stir Fan

Neg./Tun.

Feed

Evap. Cooling

Tunnel Fan

The Scroll Symbol is a
flashing down arrow (

") that

indicates more text outside of
display screen. Use up/down
editor arrow keys

bc to

scroll text.

The Link Symbol (

) is a right

pointing arrow and indicates a
link to another display screen.

To change
parameter:
Select parameter
using editor
arrow keys. Use
+ and - keys to
change value.

"

(1)Target Temp =

77.5°

(2)Ramping:

On

(3)Target Press =

0.04 wc

(4)Ramping:

Off

(5)Tunnel Press =

0.00 wc

(6)Target Humidity < 60%

(7)Light Schedule

(8)Feed Schedule

77.5°

NOTE: If Optimum Mode is turned On, the Target Conditions screen

will have differences from the standard screen shown above.