2 on/off stages, 3 natural ventilation stages – Hired-Hand Evolution Series 3000/3001 User Manual

Page 16

background image

Part No. 4801-5307 Rev 2-10

Evolution 3000 and 3001

16 of 70

"

. .

.

.

. .

.

. .

.

.

. .

.

(1)# (2)STATUS (3)MODE (4)RTEMP (5)ON (6)OFF (7)TIME
TUN OFF

CTUN

79.4°

85°

80°

1 On

Light

Ramp

2 On

Cstir

79.6° 76°

95°

None

. .

.

.

. .

.

----------- (8)TARGET

70°

---------

. .

.

.

. .

.

16 On

Cstir 79.6° 76°

95°

Min1

"

(1)# (2)STATUS (3)MODE

(4)RTEMP (5)ON (6)OFF (7)TIME

.

.

.

.

.

.

.

.

.

.

.

.

.

.

.

.

.

.

.

.

.

.

.

.

.

.

.

.

U1

On

NAT

CLOSE

73.0°

72.0°

CLOSED: NO

U2

On

N&T

CLOSE

73.0°

72.0°

CLOSED: NO

U1

Off

NAT

OPEN

73.0°

74.0°

CLOSED: NO

U2

Off

N&T

OPEN

73.0°

74.0°

CLOSED: NO

.

.

.

.

.

.

.

.

.

.

.

.

.

.

6.4.2 On/Off Stages

The On/Off stages are used for devices that do not need a variable speed capability. This portion of the
Stage Conditions screen shows how the On/Off Stages and are set.













(1) # - Identifies the On\Off stage number

or Tunnel and lists them in the order
of priority. Tunnel is not a stage
like the Stage Master and Vent
Master. This parameter is set in the
tunnel ventilation of Program Setup
screen. See Section 7.7, Tunnel
Ventilation
.

(2) Status - Indicates if the stage is currently

Timed, On, or Off.

(3) Mode - This column indicates how the

stage is programmed. Any stage can
be set to any of these modes. The
available stage options are: Off,
Heat, CSTIR, CNEG, CNEGT,
CTUN, LIGHT, FEED or CEVAP.

(4) Rtemp - The Rtemp column will indicate the

current temperature from which the stage is
operating.

(5) On – The current temperature setting for the on

point temperature of the stage.

(6) Off - The current temperature setting for the off

point temperature of the stage.

(7) Time - This column indicates if a stage is on a

timer and shows the different timers you are
allowed to put a stage on. The timer options
are: None, Min1, Min2, Var, Cool, or Opt
xx.

(8) Target – Target Temperature.

6.4.3 Natural Ventilation Stages

Natural Ventilation stages are used to open and close side curtains to allow natural ventilation.












(1) #- The stage bank either U1 or U2.
(2) Status - This column will indicate whether the machine is Off, Opening or Closing.

(3) Mode – The mode column indicates how the machine will be operating. It will be a natural curtain

"NAT" or a natural and tunnel "N&T" machine(U2 only). OPEN or CLOSE will be shown beside
the mode to show whether the specific line refers to the Open or Close function.

(4) Rtemp –The Rtemp column will indicate the current temperature the curtain machine is operating from.
(5) ON – The temperature at which the stage operates.
(6) OFF and (7) TIME – This column indicates if the machine is fully closed. When the machine is on

the closed auxiliary switch, this column will display “Yes”.