Watlow ANASOFT User Manual
Page 22
12 ANASOFT User’s Guide
Installation
The hardware consists of the following:
Two Watlow-Anafaze 8LS-P-RS controllers.
Controller #1 will be installed to handle furnace 2A with four loops of
PID control in Area A, two loops of R/S oven control also located in
Area A. The last two loops of controller #1 will be used to provide R/S
control for one of the presses located in Area A.
Controller #2 will be installed in Area B for two loops of PID control for
furnace 5B and four loops of R/S control of the two presses located in
Area B. Two loops of the controller will not be used at this time.
•
Create group AREA A with Loops 1 to 6 and the type number 01.
This will provide an overview screen with four loops from control-
ler #1 for Furn 2A and two Loops from controller #1 for oven in
AREA A.
•
Create group AREA B with Loops 9 to 10 and the type number 02.
This will display two Loops from controller #2 for Furn 5B on an
overview screen in AREA B.
•
Create group PRESS with Loops 7 to 8 and 11 to 14 and the type
number 03. This will display two Loops from controller #1 for the
press in AREA A, with four loops from controller #2 for the two
presses in AREA B.