beautypg.com

Hub view, Field view – Warner Electric SFPBC-500, SFPBC-650 User Manual

Page 29

background image

SFC-500 Bearing Mounted Clutch Coupling

Drawing I-25540

Normal Duty

Armature Shaft

.500 – 1.250

Rotor Shaft

.750 – 1.250

Static Torque

50 lb.ft.

Maximum Speed

4,000 RPM

Standard Voltage

D.C. 6, 24, 90

Customer Shall Maintain:

1.

Armature mounting shaft to be concentric
with rotor mounting shaft within .006 T.I.R.

Bore & Keyway Dimensions

Rotor

Bore Dia.

Keyway

.751/.750

.187 x .093

.876/.875

.9385/.9375
1.001/1.000

.250 x .125

1.126/1.125
1.251/1.250

Hub View

See page 44 for details

on Bushings.

Field View

2.062

Min.

Flat

4.093

5

Dia.

.062 When New

.125 Max.

.187

.281

5.328 Max

Dia.

1.500

1.750

Dia.

1.546

1.234

3.937

2.093

1.593

1.343

Removable plug

in ends for 1/2"

conduit.

3.156 Max.

2.781

.750

.218

5.218 max.

45°

3.750

For Bore & Keyway sizes

see chart.

All dimensions are nominal, unless otherwise noted.

Warner Electric • 800-825-9050

P-202-01 • 819-0482

29