Sf-650 flange mounted clutch – Warner Electric SFPBC-500, SFPBC-650 User Manual
Page 26
26
Warner Electric • 800-825-9050
P-202-01 • 819-0482
SF-650 Flange Mounted Clutch
1
2
3
5
4
7
6A
6A-1
8
8
6B-1
6B
7
Item
Description
Part Number
Qty.
1
Armature Accessory
5181-101-010
4
2
Armature
5281-111-002
1
3
Rotor Hub & Mounting Acc.
5207-101-005
1
4
Rotor
5281-751-001
1
5
Bushing*
1/2" to 1-5/8" Bore
180-0326 to 180-0344
1
6A
Field - Inside Mounted
1
6 Volt
5207-451-009
24 Volt
5207-451-012
90 Volt
5207-451-011
6A-1
Terminal Accessory
5311-101-001
1
6B
Field - Outside Mounted
1
6 Volt
5207-451-003
24 Volt
5207-451-006
90 Volt
5207-451-005
6B-1
Terminal Accessory
5311-101-001
1
7
Mounting Accessory
5321-101-002
1
8
Conduit Box
5200-101-010
1
* See page 44 for specific part numbers.
How to Order:
1.
Specify Bore Size for Item 5.
2.
Specify Voltage for Item 6.
3.
Specify Inside or Outside Mounted for Item 6.
Example:
SF-650 Clutch per I-25749 - 90 Volt 1" Bore
These units, when used in conjunction with the correct
Warner Electric conduit box, meet the stan dards of
UL508 and are listed under guide card #NMTR, file
#59164.
These units are CSA certified under file #LR11543.