Warner Electric 5301-101-010 Collector Ring User Manual
Installation instructions
Collector Ring Mounting Instructions for
Ring and Mounting Accessory 5301-101-010
Installation Instructions
P-1370
819-0033
Failure to follow these
instructions may result in product dam-
age, equipment damage, and serious or
fatal injury to personnel.
Warner Electric •
800-825-9050
Accessory 5301-101-010 includes all part num-
bers shown.
CONTACT WIRE HOLES
(2) 10-32-UNF TAP
3/8
DEEP
LOCATE THIS BETWEEN
MAGNET MOUNTING
BOLT HOLES
COUNTERBORE (2)
21/32
DIA. HOLES, IN HUB,
180° APART.
5
3/4
TO
TOP OF
BRUSH
HOLDER
CASE
7
25/32
DIA.
2x Wire Assy.
5301-954-003
2x Wire
Terminal
900-0005
2x Wire Clamp
263-0005
2x Screw
797-0049
(2) 8-32-UNC TAP
1/4
DEEP
1
1/8
MIN.
DIA.
A
DIA.
B
5/16
-18-UNC
TAP
1/2
7/8
9/16
1
1/8
2x Screw
797-0303
1.000/.984
HUB
6.769
+.002/-.000
DIA. OF
5301-749-001
6.771
+.000/-.002
DIA. OF
CUST. HUB
90°
6
7/16
B.C.
Collector Ring
5301-749-001
C
L
Customer shall machine hub to Dia. called for and axially
to dim. shown above to create a shoulder against which
the collector ring shall seat - counterbore and TAP# 10-32
two places 180° apart on 6-7/16 B.C. and 90° from center-
line between contact wire holes. Assemble collector ring to
hub and secure with screws 797-0303.
Insert terminal end of lead wires into collector ring and
mount magnet and collector ring to hub. Slip rubber caps
over wires, cut wires to proper length (so that when assem-
bled they will be taut) and strip insulation back 3/16”.
Secure a 900-0005 terminal to the end of each wire, then
assemble terminal to magnet with screw and washer. Slip
rubber caps over wire terminal and secure lead wires to
hub by means of clamp 263-0005.
Clutch
Pilot Dia.
Mounting Holes
Size
On Magnet
Bolt Circle
No. Holes
“A”
“B”
EQ Space
825
3.503
4 1/4
6
3.501
1000
5.378
6 1/8
6
5.376
1225
6.379
7 1/4
6
6.376
1525
9.002
9 3/4
12
9.000