Warner Electric SFPBC-500, SFPBC-650 User Manual
Page 25
SF-650 Flange Mounted Clutch
Drawing I-25749
Customer Shall Maintain:
1. Concentricity of field mounting pilot diameter
with rotor mounting shaft within .006 T.I.R.
2. Squareness of field mounting face with shaft
within .006 T.I.R. measured at field mounting
bolt circle.
3. Rotor mounting pilot diameter must be
concentric with shaft within .006 T.I.R.
Shaft Size
.500 – 1.625
Static Torque
95 lb.ft.
Maximum Speed
3,600 RPM
Standard Voltage
D.C. 6, 24, 90
Armature View
Field View
(Inside & Outside Mounted)
4.375 Dia.
2.822/2.820
pilot
dia.
4.625
.625
Max.
.578
Max.
.062 when new
.656
1
5/16-18
UNC-3A
.453
.968
3.500
max.
1.546
.937
6.687
Max.
Dia.
6.500
Dia.
1.812
Removable plug
in ends for 1/2"
conduit.
.358/.338 dia. (4)
holes equally
spaced on 7.250
dia.*
45°
3.750
5.750 max.
.358/.338 dia. (4)
holes equally
spaced on 7.250
dia.*
6.500
8.000
7.998
See page 9 for Details on
Drive Pin mountings.
* Mounting holes are within .010 of true position relative
to pilot diameter.
All dimensions are nominal, unless otherwise noted.
Warner Electric • 800-825-9050
P-202-01 • 819-0482
25