Test Description

Using the InfiniBand Compliance Test Suite

CATC IBTrainer InfiniBand Exerciser, August 2002

91

Ignoring Invalid Link State Settings

IgnoringInvalidStates

Item

Value

Name

IgnoringInvalidStates

Description

The ‘PortState’ field in the PortInfo of the DUT is set
to invalid values.

Topology

Simple

Initial link state

Active

Assertions

v1c07-002#05 v1c07-002#01

DUT

Channel Adapter

Prerequisites

SanityCheck

Test procedure

The 'PortState' field in the PortInfo of the DUT is set
to the invalid states 2 and 0x5..0xF.

If the link state of the tester changes from 'Active'
into another state, this indicates that the DUT react-
ed to an invalid setting, and the test fails.