Using the InfiniBand Compliance Test Suite

Test Description

84

CATC IBTrainer InfiniBand Exerciser, August 2002

Packet with Bad LVer

TD_10.2.4.1.3

TD_10.3.1.1.3

Item

Value

Name

TD_10.2.4.1.3

Description

The test is used to ensure that the DUT does not re-
spond to a packet with invalid settings in the LRH
field ‘LVer’.

Topology

Simple

Initial link state

Active

Assertions

v1c07-007#01.03

DUT

Channel Adapter

Prerequisites

SanityCheck

Test procedure

Sending SubnDirectGet(PortInfo) SMPs to the DUT
with the 'LVer'-field in the LRH set to the invalid
values 1-15. No response expected.

Item

Value

Name

TD_10.3.1.1.3

Description

The test is used to ensure that the DUT does not re-
spond to a packet with invalid settings in the LRH
field ‘LVer’.

Topology

Simple

Initial link state

Active

Assertions

v1c07-009#01.03

DUT

Switch, Router

Prerequisites

SanityCheck

Test procedure

Sending SubnDirectGet(PortInfo) SMPs to the DUT
with the 'LVer'-field in the LRH set to the invalid
values 1-15. No response expected.