beautypg.com

Teledyne LeCroy IBTrainer - IBTrainer Users Manual User Manual

Page 76

background image

Using the InfiniBand Compliance Test Suite

Test Description

76

CATC IBTrainer InfiniBand Exerciser, August 2002

TD_10.3.1.2.2

Item

Value

Name

TD_10.3.1.2.2

Description

The test is used to ensure that the DUT does not re-
spond to a packet with a DLID invalid for the DUT.

Topology

Simple

Initial link state

Active

Assertions

v1c07-010#02

DUT

Channel Adapter, Switch; Router

Prerequisites

SanityCheck

Test procedure

1 The tester sets the LMC of the DUT to 0.

2 The tester then sets the LID of the DUT and

checks if the DUT responds to that DLID.

3 Finally it sends out a packet with a DLID that is

invalid for the DUT (LID of DUT +1) expecting no

response.