Teledyne LeCroy SierraNet M408 User Manual Ver.1.50 User Manual
Page 218
![background image](/manuals/353540/218/background.png)
Teledyne LeCroy
InFusion Scenarios
216
SierraNet M408 Protocol Analyzer User Manual
The following table lists the supported Actions. Note that some of these Actions only
apply to creating sequences.
TABLE 4.5: Test State Actions in Simple Mode
Action
Description
Basic
Beep
Emits audible sound of duration selectable
via a drop‐down list.
Monitor Count
Opens a window to count the number of
Events that occur during a session. A
session is a time interval during which a
Scenario runs.
Link Control
Reconnect ‐ starts traffic pass‐through
immediately. This Action restarts traffic
after a previous disconnect command.
Once traffic is passing through, the
originator and responder resume link bring
up.
Disconnect ‐ puts both InFusion ports at
electrical idle immediately. This action is
only in effect while the scenario is running,
and the Jammer will reconnect the line
when the scenario is stopped.
DWORD Jam
Replace
DWORD
Replace DWORD.
Symbol Jam
Replace with Another
Symbol
Replaces the Symbol with the selected
Symbol.
Delete
Deletes the Symbol Jam.
Frame Jam
Insert Bytes Inside
Frame
Allows to insert up to 60 Bytes inside the
frame, at the specified offset or at the
“current” dword, meaning the dword that
caused the Event.
Modify [Keep
Length]
Allows to manipulate each dword in the
header, with the selected Action (click on
Pass though to get a drop‐down list).
Replace
Replaces the whole frame with the
selected frame.
Remove [Replace
with IDLE]
Removes the whole frame.
Truncate
Removes some of the payload, as specified
in the Frame Length.
Inject General Error FEC Parity Error
Injects a FEC error into traffic.
Sync Header Error
Injects a Sync Header error into traffic.
Invalid 10‐bit‐Error
Code
Injects invalid 10b code into the line (FC8
only).
Running Disparity
Error
Injects a Running Disparity (RD) error into
traffic(FC8 only).