InFusion Scenarios
214
SierraNet M408 Protocol Analyzer User Manual
1
Only shown in Action Properties dialog box when creating a sequence.
Inject General Error Invalid 10‐bit‐Error
Code
Injects invalid 10b code into the line (FC8
only).
Running Disparity
Error
Injects a Running Disparity (RD) error into
traffic(FC8 only).
FEC Parity Error
Injects a FEC error into traffic.
Sync Header Error
Injects a Sync Header error into traffic.
Block Error
Injects a Block error into traffic.
Order Set Error
Injects a Order Set error into traffic.
Insert
Insert New Frame
Allows to insert a whole frame as specified
from the list of available frames.
Symbol (66 Bit)
Allows to insert a Symbol 66 bits.
Pre‐captured Frame Allows to insert a Pre‐captured Frame
(Ethernet only).
Insert Bytes
Allows to insert Bytes (FC 16 only).
Ordered Set Jam
Delete
Delete an Ordered Set Jam.
Remove [Replace
with IDLE]
Remove an Ordered Set Jam or Replace
with another Ordered Set.
Replace with
Another Ordered
Set
Only replace with another Ordered Set.
Scenario Execution Stop Scenario
Stops the current Scenario. This Action
should be the only Action in a State as it
has higher priority over other Actions.
Restart All
Sequence
Restart all sequences in the Scenario.
1
Restart Current
Sequence
Restart the sequence that contains this
Action definition.
1
Branch To
Destination State
Go to a state in this Sequence.
1
Trigger Output
Sends a signal out the trigger port to the
device downstream.
Analyzer Trigger
1. The Action is to send a trigger to the
Analyzer.
2. The trigger point in the Analyzer that
caused the analyzer trigger action will not
be the selected event, it will be the
selected event with some offset.
External Trigger
Output
The Action is to cause an external trigger
output.
Capture
DWORD
Capture DWORD.
Frame
Capture Frame (Ethernet only).
Action