beautypg.com

IAI America CT4 User Manual

Page 39

background image

4. Maintenance Inspection

33

3) Move the X1, X2-axis several times with hand.

Caution: Ɣ Applying too much grease will increase the stirring resistance and may make

the ball screw easy to generate heat or make the excess grease on the ball

screw splash around with the rotation and dirt the surrounding. Do not supply

grease more than three or four times with a grease gun.

Ɣ In case the grease got into your eye, immediately go to see the doctor to get

an appropriate care.

After finishing the grease supply work, wash your hands carefully with water

and soap to rinse the grease off.