beautypg.com

Introduction, Ransburg, The ransburg electrostatic process – Ransburg Evolver 303 Solvent Applicator A11976-XXX User Manual

Page 9: Evolver 303™ solventborne spray applicators

background image

THE RANSBURG

ELECTROSTATIC

PROCESS

This process is a method for electrostatically apply-

ing coatings to objects. A power supply produces

a high voltage charge which is supplied to the

applicator, creating an electrostatic field between

the applicator and the target object. The target

is electrostatically grounded through its support

which may be either stationary or moving.

A regulated fluid system delivers coating material

to the applicator, where it is atomized forming

a spray mist. There, under the influence of the

electrostatic field, the atomized coating becomes

electrostatically charged. The charged particles

are attracted to and deposited on the grounded

target object. The forces between the charged

particles and the target are sufficient to turn over-

spray around and deposit it on the back surface

of the target. Therefore, a higher percentage of

the spray is deposited.

INTRODUCTION

EVOLVER 303™

SOLVENTBORNE SPRAY

APPLICATORS

The

Evolver 303 Spray Applicators System

will allow for the use of spray applicators or bell

applicators with minimal required down-time

during the switching process. This system can

also operate as a spray applicator system only

that later can be upgraded to allow for bell ap-

plicators to be used. Lastly, this system can

allow a user currently possessing an RMA-303

bell system to use spray applicators as well, with

minimal conver-sion required. The Evolver 303

Solventborne Applicator line

consists of both

60° and 90° single and dual-headed 100 kV au-

tomatic electrostatic applicators. Developed for

use on robots, the Evolver 303 spray applicator

incorporates a unique 1/3 turn quick-disconnect

spray head and a one piece slide over manifold

cover, providing the user an efficient tool for the

electrostatic application of coatings.

There are two single head models of the Evolver

303 Applicator (see Figure 1). Each model differs

in the applicator to axis orientation of the spray

head. These models are:

A11976-0XX 60° Single Head

A11976-1XX 90° Single Head

Two dual-head versions of the Evolver 303 Ap-

plicator are also available (see Figure 1). The

dual headed applicators are primarily used where

high volume fluid delivery is required. The dual

headed applicator is available in two different

configurations as follows:

A11976-2XX 60° Dual Head

A11976-3XX 90° Dual Head

6

Evolver 303 Robotic Atomizers - Introduction

Ransburg

AA-07-03.2