Ransburg, Low voltage cable installations, Robot spacer plate – Ransburg Evolver 303 Solvent Applicator A11976-XXX User Manual
Page 22: Table 1 - spacer plates, Evolver 303 robotic atomizers - installation
Robot Spacer Plate
The robot spacer plate is included with the robot
manifold assembly to increase life of the tubing
bundle. The extra spacing it provides increases
the bend radius of the tubes and decreases the
hose or cable stress at the connector.
There is only one way the spacer plate may be
assembled to the mounting plate. The spacer
plate has an alignment pin that may only engage
in one hole position in the robot mount plate. This
provides the final position to top dead center of
the robot.
Six (6) robot spacer plates shown in Table 1 are
available for this product.
>
If the length of the fan or atomization
air lines exceeds 30 ft. (10m), the lines
must be upsized to 1/2" ID (12mm for
metric).
NOTE
>
For the dipswitch settings for the
Evolver 303, reference the current Micro-
Pak service manual.
NOTE
LOW VOLTAGE CABLE
INSTALLATIONS
For installations utilizing the LECU5004-XX Micro-
Pak power supply, connect the low voltage cable
(79008-XX) from the robot manifold assembly to
the LECU5004-XX MicroPak controller or junction
box. If connecting to a junction box, use a junction
cable (77062-XX) to make the con-nection from
the junction box to the LECU5004-XX MicroPak.
Make connections as shown in Figure 4.
For installations utilizing the A10406-XX Evolver
MicroPak power supply, connect the low voltage
cable (A11353-XX or A11356-XX) from the robot
manifold assembly or junction box to the receptacle
on the rear of the A10406-XX power supply. To
>
Leave 12-24 inches (.30m-.61m) of
extra length on all lines to prevent extreme
tension being applied to these lines during
robot movement. This increases tubing
bundle life.
NOTE
maintain FM Approval, this cable must be secured
to the stress relief bar on the rear of the power
supply. (See "A10406-XX Evolver MicroPak
Power Supply" manual for further information on
connecting the low voltage cable.)
>
With the exception of fluid, dump, and
bearing air/paint trigger, all other pilot and
air supply lines should be bulkheaded
and their diameters increased one nom-
inal size. For example: atomization air
should be increased to a 1/2" ID (8mm)
from bulkhead plate to the volume booster.
NOTE
79107-00
ABB Robots
78983-00
Fanuc P155, 145 Robots
79131-00
Fanuc P200 Robot
A10847-00
Adapter (Kawasaki-KE610L)
A10848-00
Adapter (Motoman-PX2850)
A10849-00
Adapter (Motoman-PX2900)
A10851-00
Adapter (B & M LZ
2000)
Part # Description
TABLE 1 - SPACER PLATES
19
Evolver 303 Robotic Atomizers - Installation
Ransburg
AA-07-03.2