beautypg.com

Installation, Ransburg, Evolver 303 robotic atomizer installation – Ransburg Evolver 303 Solvent Applicator A11976-XXX User Manual

Page 18: Power supply assembly, Mounting, Electrical and fiber optic connections, Fluid connections, Typical installation

background image

INSTALLATION

EVOLVER 303 ROBOTIC

ATOMIZER

INSTALLATION

This information is intended

ONLY to indicate the

general installation parameters of this product and,

where applicable, its working relationship to other

Ransburg system components in typical use. Each

installation is unique and should be directed by an

authorized Ransburg representative or conducted

from the Ransburg installation drawings provided

for your particular installation.

POWER SUPPLY

ASSEMBLY

Refer to the most current Power Supply Unit

manuals for complete information regarding power

supply installation.

• MicroPak Control Unit (LECU5004)

(for non-FM installations)

• Stand-alone control/power supply unit

(A10406) (for FM installations)

• MicroPak Control Unit (LECU5004-31)

(for FM installations)

MOUNTING

The Evolver 303 is equipped with a quick dis-

connect assembly. The quick disconnect feature

consists of a robot plate which is permanently

attached to the robot through a wrist adapter plate

and a mating rear plate which is part of the Evolver

303 Spray Applicator assembly. The applicator

is secured to the robot plate with a threaded re-

taining ring.

ELECTRICAL AND FIBER

OPTIC CONNECTIONS

The fiber optic cable is included in the Evolver 303

tubing bundle, but not used. It is there, ready to

use, in case a user is using or chooses to use in

the future, a bell applicator, which requires the fiber

optic cable. The fiber optic connection is made on

the back of the applicator's robot plate. The fiber

optic cable comes preassembled with connectors

that are secured in place by set screws tightened

from the side of the robot plate. An adequate

ground must be provided to the mounting plate to

ensure that fluid fittings, etc. are at ground potential.

FLUID CONNECTIONS

The paint, solvent, and dump fluid tubing are con-

nected on the back of the robot plate with stainless

steel compression fittings and PFA tubing. Fluid

tubing requirements are shown in the "Signal

Identification Tables" in the "Installation" section.

TYPICAL INSTALLATION

Figure 4 shows a typical installation of the Evolver

303 and the wiring installation of the applicator

with the MicroPak.

15

Evolver 303 Robotic Atomizers - Installation

Ransburg

AA-07-03.2