beautypg.com

Ransburg – Ransburg Evolver 303 Solvent Applicator A11976-XXX User Manual

Page 41

background image

REMOVING SPRAY

APPLICATOR FROM THE

REAR MANIFOLD

ASSEMBLY

(See Figure 12)

Anytime service is required within the applicator

shroud, the applicator should be removed from the

robot mounting plate assembly. After the appli-

cator is removed from the robot, always move to

a clear, clean work area to remove the applicator

shroud and begin servicing.

1. Purge all fluid from the system and blow lines

dry with pushout air before the applicator is re-

moved.

2. All pressures must be removed, both air and

fluid, before removing the applicator. Fluid pres-

sure can be removed by actuating the applicator

trigger with the fluid regulator open.

3. Turn off the power supply to the applicator.

4. Remove applicator from robot by turning the

retaining ring [6] counter-clockwise from the

manifold robot mounting plate [2] (see Figure 12).

5. Remove spray head [5] (Figure 12) as previ-

ously described in Figure 10a.

Spray Applicator Disassembly

(See Figures 12, 13, 14, and 15)

6. Remove the four (4) screws [7] from mounting

block [3] and pull the block out of the upper man-

ifold [4] as shown in Figure 12.

7. Remove and inspect the o-rings [2, 16, and 17]

on the upper manifold [18]. Replace if necessary

(see Figure 13).

8. Remove mounting ring [6] by pulling straight

up as shown in Figure 13.

9. Remove the five (5) screws [8] from the bottom

of the mounting plate [12] (see Figure 13).

10. Remove the break-away ring [9] from the

mounting plate [12].

11. Pull down on the shroud [10] and slip it off

the applicator assembly to reveal the internal

assembly components. It may be necessary to

carefully use a flat head screwdriver between the

shroud [10] and the upper manifold [18] to pry the

two apart.

12. Remove the five (5) air bolts [7] from the bottom

of the mounting plate [12]. Inspect the five (5)

o-rings [3] located within the air bolts [7] and re-

place if necessary.

13. Remove the coil fluid tube [5] by unscrewing

the fluid fitting [4] from the valve manifold block

[11].

14. Remove the cascade plug [19] from the mount-

ing plate [12] by unscrewing the set screw located

on the side of the mounting plate [12] in-line with

the timer markings. (For set screw location see

Figure 14).

15. Slide the valve manifold block [11] and mounting

plate [12] off of the support rods [1] (see Figure 13).

16. Unscrew the five (5) support rods [1] from

the upper manifold [18] using an A11284-00 tool.

17. Remove the cascade [19] from the upper man-

ifold [18] by pulling straight down on the cascade

[19] (see Figure 13).

18. Remove the coil fluid tube [5] from the upper

manifold [18] by unscrewing the fluid fitting [4].

19. Remove the mounting plate [12] from the valve

manifold block [11] by unscrewing the three (3)

screws [13] located on the bottom of the mounting

plate [12].

20. Reassemble in reverse order making sure to

align the cascade wire plug timing mark with the

timing mark on the mounting plate [12] as shown

in Figure 14. Remember to tighten the set screw

called out in Figure 14.

21. When placing the shroud [10] back onto the

assembly, make sure to mate the edge with the

lip on the shroud [10] with the upper manifold [18],

and fit the lip of the shroud [10] into the groove on

the upper manifold [18], as shown inf Figure 13.

38

Evolver 303 Robotic Atomizers - Maintenance

Ransburg

AA-07-03.2