Energy Pulse LED
The PowerSmart+ has a red “Energy Pulse” LED for calibration. It flashes
at a constant rate when a load is applied to the meter.
There are two modes of LED operation:
•
NORMAL mode: the LED pulses indicate imported Wh at a rate
of 1,000 pulses per kWh
•
TEST mode: the LED pulses indicate either imported Wh, or
imported (inductive) varh at a rate of 10,000 pulses per
kWh/kvarh
The energy test mode can be enabled through the
Device Options
setup.
When in test mode, the energy and demand accumulators do not account
for consumed energy.