Electronics International MVP-50P User Manual
Page 74
A2.3 Yellow and Red Recording Interval:
Normally flight data will be recorded at a rate set in the USB and Data Recording screen. At the moment
any Function enters a Yellow or Red operating range, all flight data will be recorded at that time and the
record interval will be no slower than 3 seconds. Also, the moment the last Function leaves a Yellow or Red
operating range, all flight data will be recorded and the record interval will return to the level set in the USB
and Data Recording screen.